DOI 10.1186/s12880-024-01275-8
Comparison of vestibular aqueduct visualization on computed tomography and magnetic resonance imaging in patients with Ménière's disease.
Аннотация
BACKGROUND
The vestibular aqueduct (VA) serves an essential role in homeostasis of the inner ear and pathogenesis of Ménière's disease (MD). The bony VA can be clearly depicted by high-resolution computed tomography (HRCT), whereas the optimal sequences and parameters for magnetic resonance imaging (MRI) are not yet established. We investigated VA characteristics and potential factors influencing MRI-VA visibility in unilateral MD patients.
METHODS
One hundred patients with unilateral MD underwent MRI with three-dimensional sampling perfection with application optimized contrasts using different flip angle evolutions (3D-SPACE) sequence and HRCT evaluation. The imaging variables included MRI-VA and CT-VA visibility, CT-VA morphology and CT-peri-VA pneumatization.
RESULTS
The most frequent type of MRI-VA and CT-VA visualization was invisible VA and continuous VA, respectively. The MRI-VA visibility was significantly lower than CT-VA visibility. MRI-VA visibility had a weak positive correlation with ipsilateral CT-VA visualization. For the affected side, the MRI-VA visualization was negatively correlated with the incidence of obliterated-shaped CT-VA and positively with that of tubular-shaped CT-VA. MRI-VA visualization was not affected by CT-peri-VA pneumatization.
CONCLUSION
In patients with MD, the VA visualization on 3D-SPACE MRI is poorer than that observed on CT and may be affected by its osseous configuration. These findings may provide a basis for further characterization of VA demonstrated by MRI and its clinical significance.