MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1046/j.1365-4362.1999.00629.x

Медицинская библиотека · International journal of dermatology · 1999

Computerized system to enhance the clinical diagnosis of pigmented cutaneous malignancies.

Landau M, Matz H, Tur E, Dvir M, Brenner S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

An increase in the incidence of cutaneous malignant melanoma in recent years has not been accompanied by satisfactory progress in diagnostic methods. This study was carried out to evaluate a specially designed computerized image analysis system, called Derma Vision, to aid in the differentiation between malignant and benign cutaneous pigmented lesions.

METHODS

Seventy-one lesions were photographed with a digital camera and the data were analyzed by the Derma Vision system. The system assessed the variation of hues in each image, calculated the mean standard deviation of the hues, and produced a value that expressed the range of hues in the lesion. The lesions were then excised and examined histologically. The computer-assisted clinical diagnosis was correlated with the histologic diagnosis to determine the accuracy of the former.

RESULTS

Derma Vision predicted the malignant character of a lesion with 92% precision, compared with 87% accuracy based only on the clinical features.

CONCLUSIONS

This simple, inexpensive device can boost the accuracy of clinical diagnosis and provide a useful tool to the physician faced increasingly with having to determine whether pigmented lesions are malignant or benign.

Для цитирования: Landau M, Matz H, Tur E, Dvir M, Brenner S. Computerized system to enhance the clinical diagnosis of pigmented cutaneous malignancies.. International journal of dermatology. 1999. DOI: 10.1046/j.1365-4362.1999.00629.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.