Stereogram of the Living Heart, Lung, and Adjacent Structures.

Izawa Yu, Nishii Tatsuya, Mori Shumpei

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Innovations in invasive cardiovascular diagnostics and therapeutics, not only limited to transcatheter approaches but also involving surgical approaches, are based on a precise appreciation of the three-dimensional living heart anatomy. Rapid advancements in three-dimensional cardiovascular imaging technologies in the 21st century have supported such innovations through the periprocedural assessment of the clinical anatomy of the living heart. However, even if high-resolution volume-rendered images are reconstructed, they cannot provide appropriate depth perception when displayed and shared on a two-dimensional display, which is widely used in clinical settings. Currently, images reconstructed from clinical datasets can visualize fine details of the cardiovascular anatomy. Therefore, this is an optimal time for cardiologists and cardiac surgeons to revisit the classic technology, stereopsis, and obtain bonus information from carefully reconstructed clinical images. Using anaglyphs or cross/uncross-fusion of paired images, striking depth perception can be readily obtained without the need for expensive equipment. This conventional technique, when applied to high-resolution volume-rendered images, may help in obtaining appropriate diagnostics, choosing optimal therapeutics, securing procedural success, and preventing complications. Furthermore, it can be used for anatomical education. In this review, we demonstrate multiple stereoscopic images reconstructed from cardiac computed tomographic datasets and discuss their clinical and educational implications.

Для цитирования: Izawa Yu, Nishii Tatsuya, Mori Shumpei. Stereogram of the Living Heart, Lung, and Adjacent Structures.. Tomography (Ann Arbor, Mich.). 2022. DOI: 10.3390/tomography8020068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.