MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1513/annalsats.202109-1071oc

Медицинская библиотека · Annals of the American Thoracic Society · 2022

A Novel Electromagnetic Navigation Bronchoscopy System for the Diagnosis of Peripheral Pulmonary Nodules: A Randomized Clinical Trial.

Zheng Xiaoxuan, Cao Liming, Zhang Yan, Xie Fangfang, Yang Huaping, Liu Jingjing, Qu Shuoyao, Zhang Jian, Sun Jiayuan

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Rationale: Endobronchial ultrasound (EBUS) combined with a guide sheath (GS) as an instrument for confirming the proximity of the bronchoscope and its relationship to the lesion can increase the diagnostic yield when conducting transbronchial lung biopsy of peripheral pulmonary nodules (PPNs). A novel electromagnetic navigational bronchoscopy (ENB) system comprising a thinner locatable sensor probe as a guidance instrument was developed to be suitable for a thin bronchoscope with a working channel 2 mm in diameter. The diagnostic efficacy of EBUS-GS with or without this ENB system has not been confirmed.

Objectives

To compare the diagnostic value and safety of EBUS-GS with or without the ENB system for diagnosing PPNs.

Methods

A prospective, multicenter, randomized controlled clinical trial was designed and conducted at three centers. Patients with PPNs suspected to be malignant were enrolled and randomly assigned to the ENB-EBUS-GS group or the EBUS-GS group. The primary endpoint was the diagnostic yield in each group. The secondary endpoint was the procedural time and other factors affecting diagnostic yield. The safety endpoint was procedural complications.

Results

Four hundred participants were enrolled from July 2018 to October 2019, and 385 patients were analyzed, 193 in the ENB-EBUS-GS group and 192 in the EBUS-GS group. The mean nodule size was 21.7 ± 5.3 mm. The diagnostic yields were 82.9% (95% confidence interval [CI], 77.6-88.2%) in the ENB-EBUS-GS group and 73.4% (95% CI, 67.2-79.7%) in the EBUS-GS group. The difference between the two groups was 9.5% (95% CI, 2.6-16.3%), with an adjusted difference of 9.0% (95% CI, 2.3-15.8%) after adjusting for the stratification factors and center. The time to find lesions in the ENB-EBUS-GS group was shorter than in the EBUS-GS group (213.2 ± 145.6 vs. 264.8 ± 189.5 s; P = 0.003). Intraoperative hemorrhage occurred 3.6% of subjects in the ENB-EBUS-GS group and 3.1% in the EBUS-GS group, without significant differences between the two groups.

Conclusions

The novel ENB system combined with EBUS-GS demonstrated improved ability to locate PPNs, achieving a high diagnostic yield for PPNs compared with EBUS-GS alone in a safe and efficient procedure. Clinical trial registered with www.clinicaltrials.gov (NCT03569306).

Для цитирования: Zheng Xiaoxuan, Cao Liming, Zhang Yan, Xie Fangfang, Yang Huaping, Liu Jingjing, Qu Shuoyao, Zhang Jian, Sun Jiayuan. A Novel Electromagnetic Navigation Bronchoscopy System for the Diagnosis of Peripheral Pulmonary Nodules: A Randomized Clinical Trial.. Annals of the American Thoracic Society. 2022. DOI: 10.1513/annalsats.202109-1071oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.