MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000029600

Медицинская библиотека · Medicine · 2022

Comparison of pressure resistance of double-rows and triple-rows circular stapler in rectal double stapling technique: In vitro study.

Mazaki Junichi, Katsumata Kenji, Udo Ryutaro, Tago Tomoya, Kasahara Kenta, Kuwabara Hiroshi, Enomoto Masanobu, Ishizaki Tetsuo, Nagakawa Yuichi, Tsuchida Akihiko

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Anastomotic leak after gastrointestinal anastomosis is a serious complication. Anastomotic failure depends on various parameters. The aim of our study was to evaluate the pressure resistance of a new device, EEA™ circular stapler with Tri-Staple™ technology 28 mm Medium/Thick (Triple-rows circular stapler; TCS) compared with EEA™ circular stapler with DST series™ technology 28 mm, 4.8 mm staples (double-rows circular stapler; DCS).

PATIENTS AND

METHODS

We performed 30 anastomoses (DSC: 15, TCS: 15) of DST with porcine colon model in vitro. We performed following 3 comparative experiences; Experiment 1: observation of staple shape with a colonoscopy, Experiment 2: comparison of the pressure resistance, Experiment 3: comparison of leakage points.

RESULTS

There was no hypoplasia of staples and the shapes were well-formed by colonoscopy. The leakage pressure of DCS was 19.6 ± 4.4 mm Hg (mean ± standard deviation) and that of TCS was 38.6 ± 10.2 mm Hg (mean ± standard deviation). There was a significantly difference between 2 groups (P < .001). 12 cases of DCS (80%) and 10 cases of TCS (66.7%) had leakages from Circular stapler point. 2 cases of DCS (13.3%) and 5 cases of TCS (33.3%) had leakages from Crossing points. Only 1 case of DCS had leakages from Dog ear point (6.7%). There was no significantly difference in leakage site between 2 groups (P = .195).

CONCLUSIONS

TSC showed high pressure resistance during DST compared with that of DCS. It was suggested that TCS may contribute to the reduction of anastomotic leakage rate.

Для цитирования: Mazaki Junichi, Katsumata Kenji, Udo Ryutaro, Tago Tomoya, Kasahara Kenta, Kuwabara Hiroshi, Enomoto Masanobu, Ishizaki Tetsuo, Nagakawa Yuichi, Tsuchida Akihiko. Comparison of pressure resistance of double-rows and triple-rows circular stapler in rectal double stapling technique: In vitro study.. Medicine. 2022. DOI: 10.1097/md.0000000000029600.