Clinical and translational radiation oncology · 2022
The in-silico feasibility of dose escalated, hypofractionated radiotherapy for rectal cancer.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Devlin Lynsey, Grocutt Laura, Hunter Bianca, Chemu Hiwot, Duffton Aileen, McDonald Alec, Macleod Nicholas, McLoone Philip, O'Cathail Sean M
Аннотация
BACKGROUND AND PURPOSE: Short course radiotherapy (SCRT) has a low biological prescription dose. Rectal cancer has a dose response relationship and moderate α/β ratio (∼5). We hypothesise hypofractionated dose escalation has radiobiological advantages. We assessed in-silico dose escalation to the primary tumour using a simultaneous integrated boost (SIB) technique.
MATERIALS AND METHODS: Patients who had received 25 Gy/5# were enrolled. GTV was macroscopic tumour including lumen. CTVA was GTV + 10 mm. CTVB included elective nodes. PTV_Low was created from CTVF (CTVA + CTVB) + 7 mm. PTV_High (SIB) was GTV + 5 mm margin. OAR were as per RTOG guidelines. Each patient had 4 plans created at increasing dose levels (27.5 Gy, 30 Gy, 32.5 Gy and 35 Gy) to PTV_High. PTV_Low was 25 Gy/5#.5 test plans were created for each patient in Eclipse™ v15.5 and consisted of 2 VMAT full arcs (6 MV), Varian Truebeam (2.7). Planning objectives were set in the Photon optimiser (PO) and recalculated using Acuros v15.5. A priori feasibility was defined as 90% of plans achieving the planning objectives at 32.5 Gy dose level (EqD2 53.4 Gy).
RESULTS: 20 SCRT patients median age 70, F (n = 5), M (n = 15). Rectum level; low (n = 12), mid (n = 3) and upper (n = 5). 100 plans were analysed. Mean volume of PTV_High was 130 cm3 (SD 81.5) and PTV_Low 769.6 cm3 (SD 241.1). 100% plans complied with mandatory planning dose metrics for each structure at the 25 Gy/5# plan and each dose level.
CONCLUSION: Hypofractionated dose escalation to the primary tumour up to 35 Gy/5# is technically feasible in rectal cancer radiotherapy.
MATERIALS AND METHODS: Patients who had received 25 Gy/5# were enrolled. GTV was macroscopic tumour including lumen. CTVA was GTV + 10 mm. CTVB included elective nodes. PTV_Low was created from CTVF (CTVA + CTVB) + 7 mm. PTV_High (SIB) was GTV + 5 mm margin. OAR were as per RTOG guidelines. Each patient had 4 plans created at increasing dose levels (27.5 Gy, 30 Gy, 32.5 Gy and 35 Gy) to PTV_High. PTV_Low was 25 Gy/5#.5 test plans were created for each patient in Eclipse™ v15.5 and consisted of 2 VMAT full arcs (6 MV), Varian Truebeam (2.7). Planning objectives were set in the Photon optimiser (PO) and recalculated using Acuros v15.5. A priori feasibility was defined as 90% of plans achieving the planning objectives at 32.5 Gy dose level (EqD2 53.4 Gy).
RESULTS: 20 SCRT patients median age 70, F (n = 5), M (n = 15). Rectum level; low (n = 12), mid (n = 3) and upper (n = 5). 100 plans were analysed. Mean volume of PTV_High was 130 cm3 (SD 81.5) and PTV_Low 769.6 cm3 (SD 241.1). 100% plans complied with mandatory planning dose metrics for each structure at the 25 Gy/5# plan and each dose level.
CONCLUSION: Hypofractionated dose escalation to the primary tumour up to 35 Gy/5# is technically feasible in rectal cancer radiotherapy.