BACKGROUND

Prostate cancer (PCa) patients with biochemical recurrence (BCR) following radical prostatectomy or radiation therapy often present with very low prostate-specific antigen (PSA) levels (⩽0.5 ng/mL). Accurate detection of recurrence at such low levels is crucial for guiding treatment decisions.

OBJECTIVES

To assess the diagnostic efficacy of [18F]PSMA-1007 PET/MR (PSMA-PETMR) in detecting BCR of PCa in patients with very low PSA levels.

DESIGN

A prospective study conducted between May 2021 and January 2023, with data subsequently analyzed retrospectively after a 2-year follow-up.

METHODS

The cohort comprised 157 PCa patients with BCR, of whom 52 had PSA levels ⩽ 0.5 ng/mL and underwent PSMA-PETMR imaging. The imaging protocol incorporated multiparametric MRI (mpMRI) and PET acquisitions, with lesion classification following PSMA-RADS version 1.0. Detection rates of recurrent lesions, including local recurrence, lymph node metastasis, and skeletal metastasis, were evaluated.

RESULTS

PSMA-PETMR exhibited a 63.5% detection rate for recurrent PCa at low PSA levels, surpassing traditional diagnostic methods. Thirty-four local recurrences, 12 metastatic lymph nodes, and 4 skeletal metastases were identified. Follow-up imaging enhanced the detection rate to 73.1% by reclassifying initially equivocal findings. PSMA-PETMR influenced clinical decision-making in 17% of patients by facilitating personalized treatment strategies.

CONCLUSION

PSMA-PETMR significantly improves the detection of recurrent PCa in patients with very low PSA levels, offering precise lesion localization and supporting personalized treatment approaches. Further studies are needed to optimize its clinical use and validate its long-term benefits.

Для цитирования: Lin Ko-Han, Wei Tzu-Chun, Shen Shu-Huei, Huang William Ji-Shien, Chuang Mei-Hua, Peng Nan-Jing, Huang Wen-Tao, Wang Yuh-Feng. [18F]PSMA-1007 PET/MR as a Precision Biomarker for Early Detection of Biochemical Recurrence in Prostate Cancer at Very Low PSA Levels.. Biomarker insights. 2025. DOI: 10.1177/11772719251324307.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.