Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2020
A prospective observational study to analyse the influence of bladder and rectal volume changes on prostate radiotherapy using IMRT.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Arya Ramesh, Goyal Harsh, Naik Ayush, Gurjar Om Prakash
Аннотация
AIM: To analyse the interfractional bladder and rectal volume changes and the influence on prostate position.
BACKGROUND: Interfractional displacement of prostate due to variation in bladder and rectal volume is usual. It is only rational to study the bladder and rectal volume changes and their effects on prostate position during intensity modulated radiotherapy of prostate cancer.
MATERIALS AND METHODS: A prospective study was conducted on twenty patients with localized prostate cancer during the first phase of radiotherapy, where 50 gray in 25 fractions was delivered by the IMRT technique with daily cone beam computed tomography Bladder and rectum volumes were delineated on CBCT images and their volumes were noted. Prostate position was noted on each set of CBCT images with respect to specific reference points defined on the ileum and coccyx, and daily prostate displacement was noted.
RESULTS: Mean setup errors in vertical, longitudinal and lateral directions were noted as 1.49, 0.498 and 0.17 cm, respectively. Mean change in bladder and rectal volumes in daily CBCT images with respect to that on the first day CT images was noted as 101.94 and 10.22, respectively. Mean lateral and vertical displacement in prostate position was noted as 0.53 and 0.49 cm respectively. No considerable changes in dosimetric parameters were observed because of bladder and rectal volume changes.
CONCLUSIONS: Daily CBCT should be done for accurate treatment delivery by the IMRT technique for prostate radiotherapy as prostate shifts physiologically with changes in rectal and bladder volumes.
BACKGROUND: Interfractional displacement of prostate due to variation in bladder and rectal volume is usual. It is only rational to study the bladder and rectal volume changes and their effects on prostate position during intensity modulated radiotherapy of prostate cancer.
MATERIALS AND METHODS: A prospective study was conducted on twenty patients with localized prostate cancer during the first phase of radiotherapy, where 50 gray in 25 fractions was delivered by the IMRT technique with daily cone beam computed tomography Bladder and rectum volumes were delineated on CBCT images and their volumes were noted. Prostate position was noted on each set of CBCT images with respect to specific reference points defined on the ileum and coccyx, and daily prostate displacement was noted.
RESULTS: Mean setup errors in vertical, longitudinal and lateral directions were noted as 1.49, 0.498 and 0.17 cm, respectively. Mean change in bladder and rectal volumes in daily CBCT images with respect to that on the first day CT images was noted as 101.94 and 10.22, respectively. Mean lateral and vertical displacement in prostate position was noted as 0.53 and 0.49 cm respectively. No considerable changes in dosimetric parameters were observed because of bladder and rectal volume changes.
CONCLUSIONS: Daily CBCT should be done for accurate treatment delivery by the IMRT technique for prostate radiotherapy as prostate shifts physiologically with changes in rectal and bladder volumes.