m+Medelevator.RU
← Поиск публикаций
International journal of radiation oncology, biology, physics · 2022

Applying 3D-Printed Templates in High-Dose-Rate Brachytherapy for Cervix Cancer: Simplified Needle Insertion for Optimized Dosimetry.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Marar Mallika, Simiele Eric, Niedermayr Thomas, Kidd Elizabeth A

Аннотация

PURPOSE: In cervical cancer brachytherapy, adding interstitial needles to intracavitary applicators can enhance dosimetry by improving target coverage while limiting normal tissue dose. However, its use is limited to a subset of practitioners with appropriate technical skill. We designed tandem anchored radially guiding interstitial templates (TARGITs) with a 3-dimensional (3D) printing workflow to optimize needle placement and facilitate greater ease-of-use of intracavitary/interstitial (IC/IS) technique. This study compared dosimetry and procedure characteristics between tandem and ovoid (T&O) implants using TARGIT technique versus non-TARGIT technique.

METHODS AND MATERIALS: This single-institution retrospective cohort study included patients undergoing T&O brachytherapy as part of definitive radiation treatment for cervical cancer between February 2017 and January 2021. TARGIT technique was implemented from November 2019 onwards; all prior procedures involved non-TARGIT technique using a no needle or freehand needle approach. Target coverage, dose to organs at risk, and procedure times were evaluated and compared between TARGIT technique and non-TARGIT technique.

RESULTS: The cohort included 70 patients with cervical cancer who underwent 302 T&O procedures: 68 (23%) with TARGIT technique and 234 (77%) with non-TARGIT technique, which included 133 no needle and 101 freehand needle implants. TARGIT implants involved longer average procedure times (+6.3 minutes, P < .0001). TARGIT implants achieved a higher mean high-risk clinical target volume V100% than non-TARGIT implants (+4.4%, P = .001), including for large tumors 30 cm3 or greater (+8.1%, P = .002). Average D90 was 4.6 Gy higher and average D98 was 3.2 Gy higher for TARGIT technique compared with non-TARGIT technique (P = .006 and P = .02). Total treatment doses to rectum, bowel, and bladder were not significantly different for TARGIT versus non-TARGIT technique.

CONCLUSIONS: The 3D-printed TARGIT approach to T&O brachytherapy achieved greater tumor coverage while sparing normal tissues, particularly for large tumor volumes, with only a slight increase in average procedure time. TARGIT represents a creative technological solution for increasing accessibility of advanced IC/IS brachytherapy technique for cervical cancer definitive radiation treatment.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты