m+Medelevator.RU
← Поиск публикаций
European journal of radiology · 2021

Effects of BPA on right ventricular mechanical dysfunction in patients with inoperable CTEPH - A cardiac magnetic resonance study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Roller Fritz C, Schüssler Armin, Hasse Alexander, Kriechbaum Steffen, Richter Manuel, Guth Stefan, Tello Khodr, Breithecker Andreas, Liebetrau Christoph, Hamm Christian W, Mayer Eckhard, Seeger Werner, Krombach Gabriele A, Wiedenroth Christoph B

Аннотация

PURPOSE: The aim of this study was to assess effects of balloon pulmonary angioplasty (BPA) on right ventricular (RV) mechanical dysfunction in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) via MRI.

METHOD: MRI at 1.5 Tesla and right heart catheterization were performed before and 6 months after BPA in 30 CTEPH patients (mean age 63.4 ± 10.6 years; 17 female). Feature-tracking strain analysis, including global longitudinal (GLS), circumferential (GCS), and radial (GRS) strain, was performed and compared with right ventricular function, myocardial remodelling (assessed by native T1 times), and pulmonary haemodynamics (mean pulmonary arterial pressure and pulmonary vascular resistance).

RESULTS: RVEF (35.9% to 48.4%) increased and mPAP (42.1 mmHg to 33.1 mmHg) and PVR (551.8 to 377.7 dyn∙s/cm5) decreased after BPA (all p < 0.0001). Moreover, RV strain increased (GLS -19.9 to -24.0%, p = 0.0003; GCS -9.4 to -11.0%, p = 0.0022; GRS 38.2 to 50.7%, p = 0.001) and septal native area-adjusted T1 time (AA-T1) decreased (1019.4 to 988.7 ms, p < 0.0001). GLS revealed the best correlations with RVEF (before BPA r = -0.75; after BPA r = -0.54), mPAP (r = 0.36; r = 0.52), PVR (r = 0.49; r = 0.48), and AA-T1 (r = 0.44; 0.19).

CONCLUSION: RV mechanical dysfunction, pulmonary haemodynamics, and myocardial remodelling are markedly improved by BPA. Moreover, RV strain values showed good correlations with RV function, pulmonary haemodynamics, and myocardial remodelling. Therefore, strain analysis might provide new insights regarding therapy outcome, monitoring, and prognosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты