Predictive Model for the Diagnosis of Benign/Malignant Complex Cystic and Solid Breast Nodules.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liu Han, Hou Chun-Jie, Tang Jing-Lan, Liu An-Ning, Lu Ke-Feng, Liu Ying, Du Pei
Аннотация
PURPOSE: To develop an ultrasound predictive model to differentiate between benign and malignant complex cystic and solid nodules (C-SNs).
METHODS: A total of 211 patients with complex C-SNs rated as American College of Radiology Breast Imaging Reporting and Data System (ACR BI-RADS) category 4 or 5 on the ultrasound reports were included in the study, from June 2018-2021. Multivariate stepwise logistic regression analysis was used to establish a predictive model, based on clinical and ultrasound features. The diagnostic performance of the model was evaluated by the area under the curve (AUC) of the receiver operating characteristic curve.
RESULTS: A total of 109 breast nodules, including 74 benign nodules (67.89%) and 35 malignant nodules (32.11%), were detected by surgical pathology or puncture biopsy. Multivariate analysis showed that the blood flow (BF) of complex C-SNs (p = 0.03), cystic fluid transmission (p = 0.02), longitudinal diameter (p < 0.001), and age (p = 0.03) were independent risk factors for malignant complex cystic and solid breast nodules. The ultrasound model equation was Z=-12.14+2.24×X12+1.97×X20+0.40×X7+0.11×X0; M=ez1+ez (M is the malignancy score, e = 2.72). The area under the curve (AUC) was 0.89, which indicated good predictive utility for the model.
CONCLUSIONS: A prediction model incorporating major risk factors can predict the malignant C-SNs with accuracy.
METHODS: A total of 211 patients with complex C-SNs rated as American College of Radiology Breast Imaging Reporting and Data System (ACR BI-RADS) category 4 or 5 on the ultrasound reports were included in the study, from June 2018-2021. Multivariate stepwise logistic regression analysis was used to establish a predictive model, based on clinical and ultrasound features. The diagnostic performance of the model was evaluated by the area under the curve (AUC) of the receiver operating characteristic curve.
RESULTS: A total of 109 breast nodules, including 74 benign nodules (67.89%) and 35 malignant nodules (32.11%), were detected by surgical pathology or puncture biopsy. Multivariate analysis showed that the blood flow (BF) of complex C-SNs (p = 0.03), cystic fluid transmission (p = 0.02), longitudinal diameter (p < 0.001), and age (p = 0.03) were independent risk factors for malignant complex cystic and solid breast nodules. The ultrasound model equation was Z=-12.14+2.24×X12+1.97×X20+0.40×X7+0.11×X0; M=ez1+ez (M is the malignancy score, e = 2.72). The area under the curve (AUC) was 0.89, which indicated good predictive utility for the model.
CONCLUSIONS: A prediction model incorporating major risk factors can predict the malignant C-SNs with accuracy.