Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2022

Evaluation of the Relationship Between the Changes in the Corneal Biomechanical Properties and Changes in the Anterior Segment OCT Parameters Following Customized Corneal Cross-Linking.

Nishida Tomoya, Kojima Takashi, Kataoka Takahiro, Isogai Naoki, Yoshida Yoko, Nakamura Tomoaki

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study aimed to investigate the relationship between changes in corneal biomechanical properties and changes in anterior segment optical coherence tomography (AS-OCT) parameters preoperatively and following customized corneal cross-linking (C-CXL) in eyes with progressive keratoconus.

PATIENTS AND

METHODS

This study included 44 eyes of 44 patients (33 men, 11 women; average age 22.8 ± 6.4 years) who underwent C-CXL for progressive keratoconus. Scheimpflug-based tonometer (SBT) and AS-OCT findings were evaluated preoperatively and 3 months following CXL. Parameters related to changes in SBT parameters were examined by multiple regression analysis using the stepwise method.

RESULTS

Regarding SBT parameters, significant changes were observed in the integrated area under the curve of the inverse concave radius (pre, 12.19 ± 1.95/mm; post, 11.26 ± 1.89/mm; p < 0.0001), maximum inverse radius (pre, 0.24 ± 0.04/mm; post, 0.23 ± 0.04/mm; p = 0.0053), deformation amplitude ratio max 2 mm (pre, 5.53 ± 0.81; post, 5.29 ± 0.71; p = 0.0048), and stress-strain index (pre, 0.74 ± 0.16; post, 0.84 ± 0.20; p < 0.0001), pre and post C-CXL. Regarding AS-OCT parameters, significant changes were observed in average keratometry (pre, 47.87 ± 3.61 D; post, 47.56 ± 3.29 D, p = 0.0104), steep keratometry (pre, 49.61 ± 4.01 D; post, 49.25 ± 3.59 D; p = 0.0115), maximum keratometry (pre, 55.44 ± 6.22 D; post, 54.68 ± 5.56 D; p = 0.0061), and thinnest corneal thickness (pre, 450.43 ± 41.74 μm; post, 444.00 ± 39.35 μm; p < 0.0001), pre and post C-CXL. Multiple regression analysis demonstrated that when the change in the deformation amplitude (DA) ratio max (2 mm) was the dependent variable, age, change in average keratometry, and change in the thinnest corneal thickness were selected as explanatory variables. When changes in the stiffness parameter at applanation 1 and stress-strain index were the dependent variables, change in the intraocular pressure (IOP) was selected as the explanatory variable.

CONCLUSION

Change in the SBT parameters following C-CXL could be related to the age, change in the IOP value, change in average keratometry, and thinnest corneal thickness.

Для цитирования: Nishida Tomoya, Kojima Takashi, Kataoka Takahiro, Isogai Naoki, Yoshida Yoko, Nakamura Tomoaki. Evaluation of the Relationship Between the Changes in the Corneal Biomechanical Properties and Changes in the Anterior Segment OCT Parameters Following Customized Corneal Cross-Linking.. Clinical ophthalmology (Auckland, N.Z.). 2022. DOI: 10.2147/opth.s361836.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.