Influence of head positioning during cone-beam CT imaging on the accuracy of virtual 3D models.

van Eijnatten Maureen, Wolff Jan, Pauwels Ruben, Karhu Kalle, Hietanen Ari, der Sarkissian Henry, Koivisto Juha H

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Cone beam computed tomography (CBCT) images are being increasingly used to acquire three-dimensional (3D) models of the skull for additive manufacturing purposes. However, the accuracy of such models remains a challenge, especially in the orbital area. The aim of this study is to assess the impact of four different CBCT imaging positions on the accuracy of the resulting 3D models in the orbital area.

METHODS

An anthropomorphic head phantom was manufactured by submerging a dry human skull in silicon to mimic the soft tissue attenuation and scattering properties of the human head. The phantom was scanned on a ProMax 3D MAX CBCT scanner using 90 and 120 kV for four different field of view positions: standard; elevated; backwards tilted; and forward tilted. All CBCT images were subsequently converted into 3D models and geometrically compared with a "gold-standard" optical scan of the dry skull.

RESULTS

Mean absolute deviations of the 3D models ranged between 0.15 ± 0.11 mm and 0.56 ± 0.28 mm. The elevated imaging position in combination with 120 kV tube voltage resulted in an improved representation of the orbital walls in the resulting 3D model without compromising the accuracy.

CONCLUSIONS

Head positioning during CBCT imaging can influence the accuracy of the resulting 3D model. The accuracy of such models may be improved by positioning the region of interest (e.g. the orbital area) in the focal plane (Figure 2a) of the CBCT X-ray beam.

Для цитирования: van Eijnatten Maureen, Wolff Jan, Pauwels Ruben, Karhu Kalle, Hietanen Ari, der Sarkissian Henry, Koivisto Juha H. Influence of head positioning during cone-beam CT imaging on the accuracy of virtual 3D models.. Dento maxillo facial radiology. 2022. DOI: 10.1259/dmfr.20220104.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.