Respiratory physiology & neurobiology · 2021
Impact of lung structure on airway opening index during mechanical versus manual chest compressions in a porcine model of cardiac arrest.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Rezoagli Emanuele, Magliocca Aurora, Grieco Domenico Luca, Bellani Giacomo, Ristagno Giuseppe
Аннотация
OBJECTIVES: The exhaled CO2 signal provides guidance during cardiopulmonary resuscitation. The Airway opening index (AOI) has been recently used to quantify chest-compression (CC) induced expired CO2 oscillations. We aimed to determine whether levels of intrathoracic pressures developed during CC or parameters related to lung structure may affect AOI.
METHODS: Secondary analysis of a randomized animal study (n = 12) in a porcine model of cardiac arrest (CA) and cardiopulmonary resuscitation (CPR) during ambulance transport. Animals were randomized to 18-min of manual or mechanical CCs. Changes in AOI and right atrial pressure (ΔRAP) were recorded during CCs in animals undergoing manual (n = 6) or mechanical (n = 6) CCs. Lung CT scan and measurement of the respiratory system compliance (Cpl,rs) were performed immediately after return of spontaneous circulation.
RESULTS: Animals undergoing mechanical CCs had a lower AOI compared to animals treated with manual CCs (p < 0.001). AOI negatively correlated with the swings of intrathoracic pressure, as measured by the change in ΔRAP (ρ=-0.727, p = 0.007). AOI correlated with the lung density (ρ=-0.818, p = 0.001) and with the Cpl,rs (ρ = 0.676, p = 0.016). Animals with cardiopulmonary resuscitation associated lung edema (CRALE) (i.e. mean CT≥-500 HU) showed lower levels of AOI compared to animals without it (29 ± 12 % versus 50 ± 16 %, p = 0.025).
CONCLUSIONS: Animals undergoing mechanical CCs had lower levels of AOI compared to animals undergoing manual CCs. A higher swing of intrathoracic pressure during CC, a denser and a stiffer lung were associated with an impaired CO2 exhalation during CC as observed by a lower AOI.
METHODS: Secondary analysis of a randomized animal study (n = 12) in a porcine model of cardiac arrest (CA) and cardiopulmonary resuscitation (CPR) during ambulance transport. Animals were randomized to 18-min of manual or mechanical CCs. Changes in AOI and right atrial pressure (ΔRAP) were recorded during CCs in animals undergoing manual (n = 6) or mechanical (n = 6) CCs. Lung CT scan and measurement of the respiratory system compliance (Cpl,rs) were performed immediately after return of spontaneous circulation.
RESULTS: Animals undergoing mechanical CCs had a lower AOI compared to animals treated with manual CCs (p < 0.001). AOI negatively correlated with the swings of intrathoracic pressure, as measured by the change in ΔRAP (ρ=-0.727, p = 0.007). AOI correlated with the lung density (ρ=-0.818, p = 0.001) and with the Cpl,rs (ρ = 0.676, p = 0.016). Animals with cardiopulmonary resuscitation associated lung edema (CRALE) (i.e. mean CT≥-500 HU) showed lower levels of AOI compared to animals without it (29 ± 12 % versus 50 ± 16 %, p = 0.025).
CONCLUSIONS: Animals undergoing mechanical CCs had lower levels of AOI compared to animals undergoing manual CCs. A higher swing of intrathoracic pressure during CC, a denser and a stiffer lung were associated with an impaired CO2 exhalation during CC as observed by a lower AOI.