DOI 10.1016/j.resp.2021.103807
Impact of lung structure on airway opening index during mechanical versus manual chest compressions in a porcine model of cardiac arrest.
Аннотация
OBJECTIVES
The exhaled CO2 signal provides guidance during cardiopulmonary resuscitation. The Airway opening index (AOI) has been recently used to quantify chest-compression (CC) induced expired CO2 oscillations. We aimed to determine whether levels of intrathoracic pressures developed during CC or parameters related to lung structure may affect AOI.
METHODS
Secondary analysis of a randomized animal study (n = 12) in a porcine model of cardiac arrest (CA) and cardiopulmonary resuscitation (CPR) during ambulance transport. Animals were randomized to 18-min of manual or mechanical CCs. Changes in AOI and right atrial pressure (ΔRAP) were recorded during CCs in animals undergoing manual (n = 6) or mechanical (n = 6) CCs. Lung CT scan and measurement of the respiratory system compliance (Cpl,rs) were performed immediately after return of spontaneous circulation.
RESULTS
Animals undergoing mechanical CCs had a lower AOI compared to animals treated with manual CCs (p < 0.001). AOI negatively correlated with the swings of intrathoracic pressure, as measured by the change in ΔRAP (ρ=-0.727, p = 0.007). AOI correlated with the lung density (ρ=-0.818, p = 0.001) and with the Cpl,rs (ρ = 0.676, p = 0.016). Animals with cardiopulmonary resuscitation associated lung edema (CRALE) (i.e. mean CT≥-500 HU) showed lower levels of AOI compared to animals without it (29 ± 12 % versus 50 ± 16 %, p = 0.025).
CONCLUSIONS
Animals undergoing mechanical CCs had lower levels of AOI compared to animals undergoing manual CCs. A higher swing of intrathoracic pressure during CC, a denser and a stiffer lung were associated with an impaired CO2 exhalation during CC as observed by a lower AOI.