MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Georgian medical news · 2026

LOW-FREQUENCY ULTRASOUND AND OZONE/NO TECHNOLOGIES IN THE COMBINED TREATMENT OF EXUDATIVE HEMISINUSITIS USING THE YAMIK-3 SINUS CATHETER.

Ospanova M, Ospanova S, Yernazarov A, Amanbaev R, Rakhmankulov U

СтатьяПеревод пока не подготовлен

Аннотация

AIM OF STUDY: To evaluate the clinical efficacy and rate of inflammatory process regression using the YAMIK-3 sinus catheter combined with low-frequency ultrasound (LFUS) and ozone/NO technologies in the treatment of acute purulent hemisinusitis (APHS).

MATERIAL AND

METHODS

A prospective controlled clinical study enrolled 51 patients with confirmed APHS. The main group (n=25) received YAMIK-3 sinus drainage with instillation of ozone/NO-enriched physiological saline followed by combined LFUS and ozone/NO mucosal exposure. The control group (n=26) received YAMIK-3 drainage with 0.01% Miramistin instillation. Clinical symptoms, videoendoscopic findings, microbiological cultures, endogenous intoxication markers (tyrosine-containing peptides [TCP] and tryptophan-containing peptides [TrCP]), and radiological sinus pneumatisation were assessed before and after treatment.

RESULTS AND

CONCLUSIONS

Sterile post-treatment cultures were achieved in 23/25 (92.0%) of main-group patients versus 20/26 (76.9%) of controls. Pathological exudate clearance occurred 3.0±0.8 days earlier and pain/mucosal oedema resolved 2.4±0.3 days earlier in the main group. Plasma TCP and TrCP concentrations, elevated 2.6-fold before treatment, normalised following combined therapy. Complete sinus pneumatisation at 3 months was achieved in 100% of main-group patients versus 88.5% of controls. Hospital stay was reduced by approximately three days. No treatment-related adverse events were observed in either group. The combined use of YAMIK-3, LFUS, and ozone/NO technologies represents a highly effective and well-tolerated treatment strategy for APHS.

Для цитирования: Ospanova M, Ospanova S, Yernazarov A, Amanbaev R, Rakhmankulov U. LOW-FREQUENCY ULTRASOUND AND OZONE/NO TECHNOLOGIES IN THE COMBINED TREATMENT OF EXUDATIVE HEMISINUSITIS USING THE YAMIK-3 SINUS CATHETER.. Georgian medical news. 2026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.