MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ckj/sfag273

Медицинская библиотека · Clinical kidney journal · 2026

Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management.

Mussnig Sebastian, Naar Luis, Theodorakopoulou Marieta, Niknam Saeidi Janosch, Beige Joachim, Keane David, Schneditz Daniel, Sarafidis Pantelis, Wassertheurer Siegfried, Mayer Christopher C, Hecking Manfred

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ambulatory blood pressure (BP) and pulse wave characteristics (PWCs) are stronger predictors of mortality than conventional pre-/post-dialytic BP in hemodialysis. While BP is recommended to be managed primarily by reducing fluid overload (FO), associations of FO with interdialytic BP/PWCs remain unknown.

METHODS

Bioimpedance-derived FO and interdialytic 44-h BP/PWCs were analyzed at baseline and follow-up of a quality improvement project involving targeted fluid management. Trended cosinor linear mixed-effects models assessed intra-patient associations of post-dialysis FO with interdialytic BP/PWCs.

RESULTS

We analyzed 120 visits (77/43 at baseline/follow-up) from 80 patients (70% male; mean age 68 ± 14 years; median dialysis vintage 38 [18-64] months). Post-dialysis FO decreased in baseline hypervolemic patients from 2.7 ± 1.3 L to 0.9 ± 1.7 L. Every 1 L increase in post-dialysis FO at the patient level was associated with increased peripheral BP (systolic: 4.54 mmHg, P < 0.001; diastolic: 2.55 mmHg, P < 0.001), peripheral resistance (0.03 s*mmHg/mL, P = 0.011), augmentation index (1.38%, P = 0.007), wave amplitudes (forward: 0.56 mmHg, P = 0.025; backward: 0.61 mmHg, P = 0.027), reservoir pressure peak (3.83 mmHg, P < 0.001), and pulse wave velocity (0.12 m/s, P = 0.007). Higher FO was associated with decreased interdialytic slopes of all BPs, peripheral resistance, backward wave amplitude, reservoir peak pressure, and pulse wave velocity. FO interacted with circadian rhythms of stroke volume, peripheral resistance, forward wave amplitude, and excess pressure peak.

CONCLUSIONS

We showed that FO in hemodialysis is associated with increased interdialytic BP and PWCs on a patient level, and that FO blunts interdialytic BP/PWC trends. We further establish that physiological BP/PWC patterns may be associated with euvolemic fluid status, hence making the case for tailoring target weight using bioimpedance spectroscopy.

Для цитирования: Mussnig Sebastian, Naar Luis, Theodorakopoulou Marieta, Niknam Saeidi Janosch, Beige Joachim, Keane David, Schneditz Daniel, Sarafidis Pantelis, Wassertheurer Siegfried, Mayer Christopher C, Hecking Manfred. Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management.. Clinical kidney journal. 2026. DOI: 10.1093/ckj/sfag273.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.