MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6ay00683c

Медицинская библиотека · Analytical methods : advancing methods and applications · 2026

A practical HPLC-UV method for the simultaneous screening of decabromodiphenyl ethane and its debromination products in environmental matrices.

Zhang Wenrui, Lei Yongchao, Wang Yanlong, Liang Peng, Zhou Haifeng, Chen Junhui

СтатьяПеревод пока не подготовлен

Аннотация

A high-efficiency, high-performance liquid chromatography-ultraviolet detection (HPLC-UV) method was developed for the simultaneous determination of decabromodiphenylethane (DBDPE) and its eight debromination products (one nona-, four octa-, two hepta-, and one hexa-brominated compounds) in soil and water samples. Key steps in the sample preparation process, such as solid-phase extraction and liquid-liquid extraction, were systematically optimized to enhance extraction efficiency and purification. This resulted in the average recovery rate of soil and water increasing by 40% and 20%, respectively, compared with that before optimization, meeting the requirements for trace organic pollutant analysis. Using an Agilent Zorbax Eclipse PAH column (2.1 mm × 100 mm × 1.8 µm) with a mobile phase of water containing 5 mM ammonium acetate aqueous solution and acetonitrile, gradient elution (flow rate of 0.4-0.7 mL min-1) was employed. At a UV detection wavelength of 230 nm, baseline separation of all target compounds was achieved. The method demonstrated good linearity across a wide concentration range (R2 > 0.992). The method's limits of detection (LOD) and quantification (LOQ) for soil matrices ranged from 0.013-3.093 ng g-1 dry weight (dw) and 0.042-10.310 ng g-1 dw, respectively. For water matrices, the LOD and LOQ ranged from 0.250-61.860 ng L-1 and 0.833-206.200 ng L-1, respectively. The relative standard deviation (RSD) ranged from 0.27% to 1.59%, indicating high precision. The main advantage of this method is its simplicity, providing a practical screening tool for routine environmental monitoring laboratories. It can complement high-resolution mass spectrometry techniques and is suitable for large-scale environmental surveys and preliminary risk assessments of DBDPE and its transformation products.

Для цитирования: Zhang Wenrui, Lei Yongchao, Wang Yanlong, Liang Peng, Zhou Haifeng, Chen Junhui. A practical HPLC-UV method for the simultaneous screening of decabromodiphenyl ethane and its debromination products in environmental matrices.. Analytical methods : advancing methods and applications. 2026. DOI: 10.1039/d6ay00683c.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.