MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2026.346180

Медицинская библиотека · Analytica chimica acta · 2026

A proximity-allosteric Adapter unlocks Cas12a exponential amplification for versatile homogeneous assay.

Chen Feiyu, Tang Man, Liu Zhangling, Li Wuxian, Hu Xingping, Xiang Linguo, Jiang Lanxin, Ban Yanna, Wang Jing, Li Jia, Cheng Wei, Yang Tiantian

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The integration of proximity-triggered homogeneous assays with CRISPR/Cas12a offers a promising route to "mix-and-read" bioanalysis, yet early efforts have faced substantial limitations. Proximity-based recognition enabled high specificity, but often introduced steric hindrance that severely suppressed Cas12a activation. Meanwhile, conventional Cas12a systems relied on linear trans-cleavage, which struggled to achieve the aM-level sensitivity required for early disease detection. It is clear that a CRISPR/Cas12a-based assay is needed that overcomes steric hindrance, achieves exponential signal amplification, and maintains the simplicity of homogeneous detection.

RESULTS

Herein, we report a dual-functional "Smart Adapter" that seamlessly couples proximity recognition with Cas12a exponential amplification. The Smart Adapter operates as a kinetically trapped molecular cage that effectively sequesters the Cas12a activator to ensure minimal background. Target binding induces a proximity-driven allostery that unlocks this cage, liberating the activator from steric constraints to initiate Cas12a activity. This primary activation serves as a catalytic seed, triggering a cascading destabilization of the remaining Adapters. By acting as both an allosteric activator and a signal propagator, the Adapter ensures high-specificity transduction and ultrasensitive amplification. The resulting Smart Proximity-Activated Cas12a Exponential Amplification (SPACE) platform achieves a detection limit (LOD) as low as 500 aM for the BCR/ABL p210 gene and enables precise discrimination of p210 minor subtypes in clinical samples. Furthermore, the platform attains a detection sensitivity of 100 fg/mL for p-Tau217 protein.

SIGNIFICANCE: This versatile strategy provides a robust framework for precise low-abundance biomarker detection, resolving CRISPR/Cas12a bottlenecks and offering a reliable mix-and-read platform for early diagnosis.

Для цитирования: Chen Feiyu, Tang Man, Liu Zhangling, Li Wuxian, Hu Xingping, Xiang Linguo, Jiang Lanxin, Ban Yanna, Wang Jing, Li Jia, Cheng Wei, Yang Tiantian. A proximity-allosteric Adapter unlocks Cas12a exponential amplification for versatile homogeneous assay.. Analytica chimica acta. 2026. DOI: 10.1016/j.aca.2026.346180.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.