Well-tolerated intracorneal wood foreign body of 40-year duration.

Covert Douglas J, Henry Christopher R, Sheth Bhavna P

Клинический случайСтатьяПоддержка исследования: вне правительства СШАОбзорПеревод пока не подготовлен

Аннотация

PURPOSE: To report the diagnosis and management of a patient with a well-tolerated, long-standing retained intracorneal foreign body.

METHODS

We describe the case of a 62-year-old man with a 40-year-old retained wood foreign body within the posterior stroma of the cornea. To the authors' knowledge, this is the longest standing intracorneal foreign body reported in the literature.

RESULTS

The foreign body was asymptomatic, well tolerated, and appeared encapsulated, so the patient was carefully observed. One year later, the examination remained stable.

CONCLUSIONS

Our case seems to violate the classic teaching that some inorganic intracorneal foreign bodies are well tolerated, whereas organic foreign bodies are poorly tolerated. It is possible that foreign organic material--if early infection is avoided--can be well tolerated by the eye.

Для цитирования: Covert Douglas J, Henry Christopher R, Sheth Bhavna P. Well-tolerated intracorneal wood foreign body of 40-year duration.. Cornea. 2009. DOI: 10.1097/ico.0b013e3181901e1f.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.