m+Medelevator.RU
← Поиск публикаций
Journal of affective disorders · 2026

Utilizing stimulation-evoked hemodynamic activity to predict antidepressant response to intermittent theta-burst stimulation in adults with major depression.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kan Rebecca L D, Tang Alvin H P, Qin Penny P, Jin Minxia, Xia Adam W L, Zhang Bella B B, Lin Tim T Z, Wang Sharie X, Lin Jessie J, Yeung Michael K, Chan Sherry K W, Li Fan, Vila-Rodriguez Fidel, Fong Kenneth N K, Padberg Frank, Kranz Georg S

Аннотация

BACKGROUND: The instantaneous neural response to prefrontal theta burst stimulation (TBS) may serve as predictive marker for antidepressant treatment success. This study aimed to (1) assess whether baseline theta burst stimulation (TBS)-induced prefrontal hemodynamic responses can predict treatment outcome of four weeks of TBS in adults with major depressive disorder (MDD); (2) assess the test-retest reliability of TBS-induced hemodynamic responses.

METHODS: Forty-four MDD participants were recruited and underwent two consecutive-day concurrent TBS/functional near-infrared spectroscopy (fNIRS) measurements. Participants then received four weeks intermittent TBS (iTBS) treatment. An additional 45 healthy controls (HCs) were recruited for the test-retest reliability analysis. Baseline TBS-induced hemodynamic responses were utilized to classify treatment responders via logistic regression and supervised machine learning. Intraclass correlation coefficients (ICCs) were calculated using a two-way mixed-effects model with absolute agreement to assess the test-retest reliability of TBS-induced hemodynamic responses.

RESULTS: A logistic regression model distinguished responders from non-responders (R2 = 0.617, p < 0.001) and a support-vector machine classifier achieved an accuracy of 82.9% and an AUC of 0.902 in identifying responders. The test-retest reliability of TBS-induced prefrontal hemoglobin responses (Single Measures ICCs) ranged from 0.301 to 0.752, suggesting poor to excellent reliability.

CONCLUSIONS: TBS-induced prefrontal hemodynamic response provides valuable information for predicting antidepressant treatment response, highlighting its potential as predictive imaging marker. The reliability of TBS-induced prefrontal response is comparable to previous neuroimaging marker studies, although better control of external factors is needed to enhance reliability.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты