MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacadv.2026.103301

Медицинская библиотека · JACC. Advances · 2026

Feasibility and Safety of Transthoracic Echocardiography-Guided Transvenous Permanent Pacemaker Implantation Without Fluoroscopy.

Feng Tianjie, Li Ziping, Dong Jie, Zhao Guangzhi, Wang Cheng, Dong Jing, Pan Xiangbin

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Fluoroscopy is routinely used for transvenous permanent pacemaker implantation, but a standardized transthoracic echocardiography (TTE)-only workflow has not been prospectively evaluated.

OBJECTIVES

The objective of the study was to evaluate the feasibility, acute safety, and procedural performance of fluoroscopy-free transvenous pacemaker implantation guided exclusively by TTE.

METHODS

In this prospective, single-center feasibility study (RADIANCE [Radiation-free Anatomical Direct Imaging Approach for No-fluoroscopy Cardiac Electrode Implantation]; NCT07458724), 52 consecutive patients referred to the Department of Structural Heart Disease were screened. Thirty-one selected patients (59.6%) with guideline-based pacing indications and adequate prespecified supine TTE acoustic windows underwent attempted TTE-only implantation. Acute procedural success required completion without fluoroscopic conversion and fulfillment of prespecified TTE-defined anatomical, electrical, and safety criteria.

RESULTS

TTE-only implantation was successful in 30/31 patients (96.8%; 95% CI: 83.3-99.9), with fluoroscopic conversion in 1/31 (3.2%). The mean procedure time was 55.4 ± 5.6 minutes. No major acute procedural complications occurred. During a median follow-up of 8.8 months (IQR: 6-12 months), atrial lead dislodgement requiring revision occurred in 1/21 dual-chamber recipients (4.8%; 95% CI: 0.1-23.8). Procedure time decreased with chronological case order (-0.59 minutes/case; Newey-West 95% CI: -0.68 to -0.49), an exploratory team-level association.

CONCLUSIONS

In selected patients with adequate supine acoustic windows, TTE-guided fluoroscopy-free pacemaker implantation was feasible with acceptable acute outcomes. The lead-position findings and exploratory case-order association require further validation in larger and more diverse populations.

Для цитирования: Feng Tianjie, Li Ziping, Dong Jie, Zhao Guangzhi, Wang Cheng, Dong Jing, Pan Xiangbin. Feasibility and Safety of Transthoracic Echocardiography-Guided Transvenous Permanent Pacemaker Implantation Without Fluoroscopy.. JACC. Advances. 2026. DOI: 10.1016/j.jacadv.2026.103301.