BACKGROUND

Though emphasized as a quality metric, sepsis quality measure (SEP-1) compliance remains low nationwide. Electronic health record (EHR)-based interventions show promise, but few have examined EHR laboratory reference value misconfiguration as a distinct driver of noncompliance.

LOCAL PROBLEM: The San Francisco Veterans Affairs, a 110-bed tertiary care center, recorded 3 consecutive quarters of SEP-1 composite performance in the lowest national quintile, nadiring at 31.5%.

METHODS

A multidisciplinary team applied LEAN-A3 methodology to identify root causes of low SEP-1 performance and design targeted countermeasures. The primary outcome was the percentage of suspected sepsis patients with a serum lactate >2.0 mmol/L who received a repeat lactate within 6 hours. Balancing measures included unnecessary repeat lactates and sepsis mortality.

INTERVENTIONS: Three EHR-based interventions were implemented between August and November 2025: (1) an Emergency Department Sepsis order-set embedding dual time-spaced lactate orders; (2) a structured Sepsis Evaluation Note template; and (3) a clinical decision support alert for patients with serum lactate >2.0 mmol/L, implemented to address a laboratory reference range misconfiguration.

RESULTS

Postintervention lactate reassessment compliance rose 14 percentage points (54%-68%), meeting Institute for Healthcare Improvement criteria for special cause variation. Facility 12-month rolling performance rose from 31.5% (lowest quintile) to 64.7% (middle quintile), reaching a quarterly high of 74.3%. No increase in unnecessary repeat lactates or sepsis mortality was detected.

CONCLUSIONS

EHR-embedded structural interventions produced sustained SEP-1 improvement without impacting laboratory utilization or mortality, offering a reproducible model for improvement through systems redesign rather than education alone.

Для цитирования: Zhang Justin C, Javaherian Kavon, Zapata Josue, Duffy Ryan, Lu Chuanyi M, Price Erika, Snowden Helena, Agarwal Anil, Mihara Kip. Electronic Health Record-Embedded Structural Interventions to Improve Sepsis Bundle Quality Measure Performance: A Quality Improvement Initiative at a Veterans Affairs Medical Center.. American journal of medical quality : the official journal of the American College of Medical Quality. 2026. DOI: 10.1097/jmq.0000000000000357.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.