Second-Look Ultrasound for MRI-Detected Lesions: MRI Features, Detection Rate, and Sonographic Findings.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Guven Selda, Hekimoglu Baki, Arikok Ata T, Durur-Subasi Irmak
Аннотация
BACKGROUND: Second-look US emerged as a feasible tool to evaluate MRI-detected lesions, although data regarding the accuracy and optimal lesion selection for second-look US is limited. Therefore, we evaluated the second-look US detection rate of breast lesions detected initially on MRI by using MRI features and compared second-look US findings across benign and malignant lesions.
MATERIAL AND METHODS: A total of 110 MRI-detected lesions subsequently evaluated with the second-look US were retrospectively reviewed. The performance of MRI features in the prediction of second-look US detection was evaluated with ROC analyses.
RESULTS: The positive and negative predictive values of second-look US for malignancy detection were 28.8% and 96.1%, respectively. In multivariate analyses, the MRI BI-RADS category (OR: 11.896, p < 0.001) and lesion type (OR: 9.470, p = 0.001) were significantly associated with second-look US detection. Combined scoring with these factors could predict second-look US detection [AUC: 0.712, 95% CI: 0.617-0.807 p < 0.001]. Furthermore, lesions with irregular shapes and margins were more often malignant in the analysis of US findings (p < 0.001).
CONCLUSIONS: The MRI BI-RADS category and lesion type could predict detection in the second-look US for MRI-detected lesions. Besides, second-look US could give additional information to distinguish between benign and malignant masses.
MATERIAL AND METHODS: A total of 110 MRI-detected lesions subsequently evaluated with the second-look US were retrospectively reviewed. The performance of MRI features in the prediction of second-look US detection was evaluated with ROC analyses.
RESULTS: The positive and negative predictive values of second-look US for malignancy detection were 28.8% and 96.1%, respectively. In multivariate analyses, the MRI BI-RADS category (OR: 11.896, p < 0.001) and lesion type (OR: 9.470, p = 0.001) were significantly associated with second-look US detection. Combined scoring with these factors could predict second-look US detection [AUC: 0.712, 95% CI: 0.617-0.807 p < 0.001]. Furthermore, lesions with irregular shapes and margins were more often malignant in the analysis of US findings (p < 0.001).
CONCLUSIONS: The MRI BI-RADS category and lesion type could predict detection in the second-look US for MRI-detected lesions. Besides, second-look US could give additional information to distinguish between benign and malignant masses.