Predictors of Heart Failure Hospitalization in Patients with the First Marketed Leadless Pacemaker -Micra VR.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Matsumura Mikiko, Minamiguchi Hitoshi, Shibuya Yuki, Sakio Takashige, Kanda Takashi, Mori Naoki, Sotomi Yohei, Sakata Yasushi, Iida Osamu
Аннотация
INTRODUCTION: Micra VR, the first leadless pacemaker, offers a high effectiveness and lower complication rate than conventional transvenous pacemakers. However, little is known about heart failure hospitalization after Micra VR implantation. We investigated the incidence and predictors of heart failure hospitalization in patients who underwent de novo Micra VR implantations.
METHODS: Ninety-four consecutive patients who underwent de novo Micra VR implantation (mean age 84.6±6.9 years, 45 males) were enrolled. Clinical outcomes were evaluated during follow-up, and predictors of heart failure hospitalization were assessed.
RESULTS: During the mean follow-up period of 640±392 days, 17 (18.1%) patients were hospitalized due to heart failure post-implantations. Heart failure hospitalization was associated with a history of atrial fibrillation and reduced left ventricular ejection fraction (LVEF≤50%). Multivariate analysis revealed that a history of AF (hazard ratio [HR], 5.77; 95% confidence interval [CI], 1.64-20.3; P = 0.006) and reduced LVEF (LVEF≤50%) (HR, 7.04; 95% CI, 1.89-26.2; P = 0.004) were independent risk factors for heart failure hospitalization. hospitalization.
CONCLUSION: The presence of AF history and reduced LVEF were predictors of heart failure hospitalization in patients with Micra VR.
METHODS: Ninety-four consecutive patients who underwent de novo Micra VR implantation (mean age 84.6±6.9 years, 45 males) were enrolled. Clinical outcomes were evaluated during follow-up, and predictors of heart failure hospitalization were assessed.
RESULTS: During the mean follow-up period of 640±392 days, 17 (18.1%) patients were hospitalized due to heart failure post-implantations. Heart failure hospitalization was associated with a history of atrial fibrillation and reduced left ventricular ejection fraction (LVEF≤50%). Multivariate analysis revealed that a history of AF (hazard ratio [HR], 5.77; 95% confidence interval [CI], 1.64-20.3; P = 0.006) and reduced LVEF (LVEF≤50%) (HR, 7.04; 95% CI, 1.89-26.2; P = 0.004) were independent risk factors for heart failure hospitalization. hospitalization.
CONCLUSION: The presence of AF history and reduced LVEF were predictors of heart failure hospitalization in patients with Micra VR.