MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000337440

Медицинская библиотека · Acta cytologica · 2012

Importance of the residual volume of the cytological solution for the reproducibility of the hybrid capture 2 high-risk human papillomavirus DNA test.

Catteau Xavier, Vanhaeverbeek Michel, Noël Jean-Christophe

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Human papillomavirus (HPV) infections are widespread in all human populations, and a large number of studies have demonstrated a relationship between high-risk (HR)-HPV infections and cervical intraepithelial neoplasia or invasive cervical cancer. To the best of our knowledge, no independent study clearly demonstrates the importance of the quantity of residual liquid after cytology in terms of sensitivity for HR-HPV detection.

STUDY

DESIGN

We conducted a study to assess the relationship between the liquid-based cytology volume and the sensitivity of the hybrid capture 2 test for the detection of HR-HPV in 23 cytological high-grade squamous intraepithelial lesions with a cervical intraepithelial neoplasia grade 2 or worse protocol on biopsy.

RESULTS

Although the sensitivity of the tests showed no statistically significant differences, we still found a significant variation in the median values of relative light units/control according to the amount of liquid used.

CONCLUSIONS

If 2 ml of liquid is used, this could lead to false negatives when the value of relative light units/control is only slightly greater than 1. The fact that we found a lower viral load at 2 versus 4 or 8 ml was also important in terms of predicting the evolution of cervical lesions. We recommend using at least 4 ml of the PreservCyt solution for HR-HPV detection with the hybrid capture 2 test.

Для цитирования: Catteau Xavier, Vanhaeverbeek Michel, Noël Jean-Christophe. Importance of the residual volume of the cytological solution for the reproducibility of the hybrid capture 2 high-risk human papillomavirus DNA test.. Acta cytologica. 2012. DOI: 10.1159/000337440.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.