Acta cytologica · 2012
Application of a new liquid-based procedure (TACAS) for the screening of cervical cancer: a preliminary study.
Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kuramoto Hiroyuki, Iwami Yoshiko, Sugimoto Naoko, Kato Chizuyo, Sugahara Takashi, Iida Manichi
Аннотация
OBJECTIVE: To evaluate the usefulness of a new liquid-based cytological procedure in a population screening program for cervix cancer.
SUBJECTS AND METHODS: Subjects were 1,000 women who underwent primary screening at the Kanagawa Health Service Association. The cytological specimens obtained by either cotton stick and Cytobrush® or Cervex-Brush® were processed using the Thinlayer Advanced Cytology Assay System (TACAS™), following the manufacturer's instructions.
RESULTS: (1) Cells were evenly distributed on specimens and stained evenly; (2) shrinkage of cells was 5% based on measurement of the nuclear diameters of granulocytes in comparison with those of the conventional procedure; (3) incidences of cells that occupied the whole area, 1/20≤, 1/4≤, 1/4> of the observation fields were 58.8, 26.2, 12.0 and 3.0%, respectively; (4) number of the squamous cells in cases with 1/4> was <5,000, in which specimen cells were correctly obtained from the squamocolumnar junction except in 3 cases (0.3%); (5) bleeding at cellular sampling was 5%, but did not disturb cell analysis; (6) inflammation caused by organisms was easily diagnosed; (7) detection rate of abnormal cytology was 4.3%, including ASC-US in 2.8% and ASC-H in 0.1%.
CONCLUSION: TACAS is a feasible and useful cytological procedure.
SUBJECTS AND METHODS: Subjects were 1,000 women who underwent primary screening at the Kanagawa Health Service Association. The cytological specimens obtained by either cotton stick and Cytobrush® or Cervex-Brush® were processed using the Thinlayer Advanced Cytology Assay System (TACAS™), following the manufacturer's instructions.
RESULTS: (1) Cells were evenly distributed on specimens and stained evenly; (2) shrinkage of cells was 5% based on measurement of the nuclear diameters of granulocytes in comparison with those of the conventional procedure; (3) incidences of cells that occupied the whole area, 1/20≤, 1/4≤, 1/4> of the observation fields were 58.8, 26.2, 12.0 and 3.0%, respectively; (4) number of the squamous cells in cases with 1/4> was <5,000, in which specimen cells were correctly obtained from the squamocolumnar junction except in 3 cases (0.3%); (5) bleeding at cellular sampling was 5%, but did not disturb cell analysis; (6) inflammation caused by organisms was easily diagnosed; (7) detection rate of abnormal cytology was 4.3%, including ASC-US in 2.8% and ASC-H in 0.1%.
CONCLUSION: TACAS is a feasible and useful cytological procedure.