MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/aog.0b013e3182234f5e

Медицинская библиотека · Obstetrics and gynecology · 2011

Management of hematocervix after loop electrosurgical excision procedure.

Perino Alexander C, Python Johanne, Thompson L Chesney

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Management is not established for the uncommon complication of cervical stenosis secondary to a loop electrosurgical excision procedure resulting in a hematocervix.

CASE: A premenopausal woman underwent an electrosurgical procedure performed without complications and subsequently developed amenorrhea. The patient was determined to have developed a hematocervix secondary to the electrosurgical procedure. Increasingly aggressive methods were attempted to drain the hematocervix, finally with successful drainage being accomplished with the use of a manual vacuum aspirator. A catheter was then used to maintain patency of the cervical canal as it re-epithelialized.

CONCLUSION

Manual vacuum aspiration and placement of a catheter to allow for re-epithelialization is a successful strategy to deal with hematocervix caused by electrosurgical procedures.

Для цитирования: Perino Alexander C, Python Johanne, Thompson L Chesney. Management of hematocervix after loop electrosurgical excision procedure.. Obstetrics and gynecology. 2011. DOI: 10.1097/aog.0b013e3182234f5e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.