m+Medelevator.RU
← Поиск публикаций
Cancer cytopathology · 2010

Accuracy of liquid-based cytology: comparison of the results obtained within a randomized controlled trial (the New Technologies for Cervical Cancer Screening Study) and an external group of experts.

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Confortini Massimo, Bergeron Christine, Desai Mina, Negri Giovanni, Dalla Palma Paolo, Montanari Gioia, Pellegrini Antonella, Ronco Guglielmo, New Technologies for Cervical Cancer Screening Study Cytology Group

Аннотация

BACKGROUND: In the New Technologies for Cervical Cancer Screening (NTCC) randomized controlled trial, no significant increase in the sensitivity of liquid-based cytology (LBC) was observed compared with conventional cytology. Both were interpreted by cytologists who had limited previous LBC experience. The objective of the current study was to assess whether different results could be expected with experienced LBC interpreters.

METHODS: A stratified, random sample of 818 LBC slides from the NTCC study was obtained. These slides were reviewed blindly and independently by 3 international experts who did not participate in the NTCC. The sensitivity and specificity of external experts were estimated for cervical intraepithelial neoplasia grade 2 or greater (CIN2+) and for CIN3+ histology, and the differences were compared with the sensitivity and specificity of the original cytologic interpretation using cutoffs of atypical squamous cells of undetermined significance (ASCUS) and low-grade squamous intraepithelial lesion (LSIL).

RESULTS: With the endpoint of CIN2+ histology, the difference in sensitivity between external experts and the original interpretation was -5.3 (95% confidence interval [CI], -16.0 to 5.4) with ASCUS as the cutoff and 3.8 (95% CI, -8.2 to 15.8) with LSIL as the cutoff. External experts had slightly lower specificity using ASCUS as the cutoff (-3.4; 95% CI, -3.9 to -2.9) and LSIL as the cutoff (-0.7; 95% CI, -1.0 to -0.4).

CONCLUSIONS: The accuracy of the external experts' interpretation was similar to that of the original interpretation. Therefore, the current results indicated that LBC is not expected to increase sensitivity even if it is used by interpreters who have extensive experience with this technique.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты