MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vcp.70140

Медицинская библиотека · Veterinary clinical pathology · 2026

Stability of Complete Blood Count Parameters in Rats and Rabbits: Impact of Blood Sampling Volume and Storage Time on Analytical Reliability.

Huang Yan-Ni, Li Yi-Ling, Xie Yu-Han, Ling Jian-An, Chen Rui-Ze, Fu Song-Wen, Xie Jing, Aschner Michael, Jiang Yue-Ming

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In laboratory practice, complete blood count (CBC) analysis is not always immediate, and underfilled or overfilled blood tubes may yield misleading results.

OBJECTIVES

To assess CBC stability in rats and rabbits over 24 h and determine the effect of under- or over-filled tubes on alterations in the results, demonstrating which indices remain reliable under these conditions.

METHODS

Blood was collected into EDTA-K2 vacuum tubes from rats (tubes: 0.5, 1.0, 1.5, 2.0 mL) and rabbits (tubes: 2.0, 2.5 mL). All tubes were stored at 4°C and analyzed at 0, 4, 8, and 24 h using a CBC analyzer.

RESULTS

Statistically significant changes (p < 0.05) were observed: In rats, white blood cell (WBC), neutrophil, lymphocyte, monocyte, red blood cell (RBC), hematocrit (HCT), and hemoglobin (Hb) counts were sensitive to blood sampling volume and decreased with smaller volumes. WBC, neutrophil, RBC, HCT, and platelet (PLT) counts showed no statistically significant change within 24 h. In rabbits, blood sampling volume and storage time independently influenced WBC, neutrophil, lymphocyte, and Hb counts. RBC, HCT, and PLT counts showed no statistically significant change within 8 h.

CONCLUSIONS

WBC, neutrophil, lymphocyte, RBC, HCT, and Hb are volume-sensitive in rats and rabbits, whereas PLT counts are unaffected by volume. Therefore, blood samples with insufficient or excessive fill may still be used for PLT measurement, but results for the other indices are not recommended.

Для цитирования: Huang Yan-Ni, Li Yi-Ling, Xie Yu-Han, Ling Jian-An, Chen Rui-Ze, Fu Song-Wen, Xie Jing, Aschner Michael, Jiang Yue-Ming. Stability of Complete Blood Count Parameters in Rats and Rabbits: Impact of Blood Sampling Volume and Storage Time on Analytical Reliability.. Veterinary clinical pathology. 2026. DOI: 10.1111/vcp.70140.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.