MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/tp.0000000000005913

Медицинская библиотека · Transplantation · 2026

Urine Ammonium During Normothermic Machine Perfusion as a Marker of Donor Kidney Function.

Ballester Bergada Cristina, Andersen Jesper Frank, Lantinga Veerle A, Kollerup Benjamin, Hamelink Tim L, Staulund Jesper, Pedersen Michael, Jaynes Chris, Leuvenink Henri, Lohmann Stine, Leipziger Jens, Keller Anna Krarup, Moers Cyril, Berg Peder, Eijken Marco

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Optimizing graft selection remains a central priority, and normothermic machine perfusion (NMP) provides a potential platform for pretransplant organ assessment. Kidney ammonium excretion quantifies proximal tubular and interstitial function. This study investigated urine ammonium during NMP as a marker of kidney graft function.

METHODS

Ammonium concentrations were measured in both perfusate and urine during 4 h of NMP in porcine kidneys exposed to controlled warm ischemia and in discarded human donor kidneys. Using a porcine autotransplant model, NMP urine ammonium was examined in relation to posttransplant outcomes.

RESULTS

Urine ammonium during NMP was reduced in ischemic porcine kidneys. At 4 h of NMP, higher urine ammonium concentration correlated with improved posttransplant kidney function, while other NMP parameters showed weaker or no correlation. In discarded human kidneys, NMP urine ammonium was highly variable and independent of kidney donor profile index, glomerulosclerosis, donor type, age, or preservation technique, indicating potential additive value beyond current assessment criteria. The findings remained robust after adjustment for urine flow, urine creatinine, and perfusate pH.

CONCLUSIONS

Urine ammonium during NMP may provide additional functional information about kidney graft quality. Its association with posttransplant function supports further investigation as a potential adjunct to current assessment criteria.

Для цитирования: Ballester Bergada Cristina, Andersen Jesper Frank, Lantinga Veerle A, Kollerup Benjamin, Hamelink Tim L, Staulund Jesper, Pedersen Michael, Jaynes Chris, Leuvenink Henri, Lohmann Stine, Leipziger Jens, Keller Anna Krarup, Moers Cyril, Berg Peder, Eijken Marco. Urine Ammonium During Normothermic Machine Perfusion as a Marker of Donor Kidney Function.. Transplantation. 2026. DOI: 10.1097/tp.0000000000005913.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.