DOI 10.1016/j.ajoint.2026.100308
Recorded ocular diagnoses in adults with homocystinuria: A propensity score-matched cohort study.
Аннотация
PURPOSE: To compare ocular diagnoses in adults with and without homocystinuria (HCU), including vitreous degeneration in a large, real-world cohort.
DESIGN
Retrospective propensity score-matched cohort study.
PARTICIPANTS
658 adults with HCU and 658 propensity score-matched controls without HCU.
METHODS
Using the U.S. TriNetX Research Network, patients with HCU were matched to controls by demographic characteristics and systemic comorbidities associated with ocular disease. Outcomes included cataract, glaucoma, dry eye disease, vitreous degeneration, myopia, and age-related macular degeneration. Patients with the corresponding diagnosis before the ophthalmic index encounter were excluded from primary time-to-event analyses. Cox models estimated hazard ratios (HRs); log-rank P values were Holm-adjusted across six outcomes. A secondary analysis included diagnoses recorded before or after index.
RESULTS
Vitreous degeneration was recorded after index in 45/581 patients with HCU (7.75%) and 29/607 controls (4.78%). HCU was associated with a higher risk of first recorded vitreous degeneration (HR, 1.77; 95% CI, 1.11-2.82; nominal P = 0.016), but not after Holm correction (adjusted P = 0.094). HCU was not significantly associated with other common eye diseases including cataract, glaucoma, AMD, myopia, and DED. Ectopia lentis could not be meaningfully evaluated because the number of recorded cases was below the TriNetX minimum reportable sample size. In the secondary analysis, vitreous degeneration was recorded in 74/658 patients with HCU (11.25%) and 50/658 controls (7.60%; prevalence ratio, 1.48; 95% CI, 1.05-2.08; nominal P = 0.024).
CONCLUSION
HCU was associated with a higher risk of vitreous degeneration, but the primary association did not remain significant after multiplicity correction. Prospective studies using standardized ophthalmic assessments are needed to determine whether this signal represents a reproducible HCU-related vitreous phenotype.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.