MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fbioe.2026.1914058

Медицинская библиотека · Frontiers in bioengineering and biotechnology · 2026

Biomechanical and clinical evaluation of the posterosuperior screw in-out-in in the inverted triangular cannulated screws fixation of femoral neck fractures.

Zhang Jian, Xu Jihai, Zou Huan, Huang Yaopeng, Tang Xin, Chen Hong, Wang Xin

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study is to evaluate the mechanical performance and clinical outcomes of the posterosuperior screw In-Out-In (IOI) and All-In in the inverted triangular cannulated screws fixation of femoral neck fractures.

METHODS

Comparison of the mechanical properties of three inverted triangular cannulated screws fixation configurations, IOI, All In-Low (AI-L), and All In-Narrow (AI-N), for femoral neck fractures with different Pauwels angles using finite element analysis. Biomechanical experiments involving torsion, anteroposterior compression, axial compression, and cyclic loading were conducted using ORTHObones artificial femurs. We retrospectively analyzed postoperative data from 91 patients with femoral neck fractures. Based on hip CT scans, patients were divided into the IOI group (32 cases) and the All-In group (59 cases), and the incidence of nonunion and avascular necrosis (AVN) of the femoral head were compared between the two groups.

RESULTS

Finite element and biomechanical experiments demonstrated that the IOI group exhibited superior performance compared to the AI-L and AI-N groups in terms of torsional, bending, shear, and fatigue resistance. The clinical follow-up revealed that the incidence of nonunion in the IOI and All-In groups was 9.38% and 8.47%, respectively, and the incidence of AVN was 15.63% and 15.25%, with no statistically significant differences between the groups (P > 0.05).

CONCLUSION

Our study demonstrated that the IOI configuration exhibited superior mechanical performance compared to the All-In configuration, while not increasing the risk of nonunion or AVN, and thus may not justify repeated fluoroscopy to avoid this trajectory. However, given the retrospective nature and limited sample size, these conclusions require confirmation through larger prospective studies with longer follow-up.

Для цитирования: Zhang Jian, Xu Jihai, Zou Huan, Huang Yaopeng, Tang Xin, Chen Hong, Wang Xin. Biomechanical and clinical evaluation of the posterosuperior screw in-out-in in the inverted triangular cannulated screws fixation of femoral neck fractures.. Frontiers in bioengineering and biotechnology. 2026. DOI: 10.3389/fbioe.2026.1914058.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.