MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5624/isd.20260111

Медицинская библиотека · Imaging science in dentistry · 2026

Comparison between dual-angle periapical technique and cone-beam computed tomography in the identification of a second canal in mandibular incisors in the presence of a zirconia implant: An in vitro study.

Andrade-Bortoletto Maria Fernanda Silva, de Oliveira Fernanda Rodrigues, Silva Thaísa Pinheiro, Réa Marcela Tarosso, Leal Renata Maira de Souza, Ruiz Débora Costa, Freitas Deborah Queiroz

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the accuracy of the dual-angle periapical technique (DPT) and CBCT acquired with two protocols in identifying lower incisors with a second canal adjacent to a zirconia implant.

MATERIALS AND

METHODS

Twenty single-rooted lower incisors were used, twelve with one canal and eight with two canals, confirmed with micro-CT. These roots and a zirconia implant were positioned in the alveolus of the mandibular right and left central incisors of a dry human mandible, respectively. Periapical radiographs were obtained using a Focus X-ray unit and a photostimulated phosphor plate (VistaScan system) with parameters of 70 kVp, 7 mA, and 0.125 seconds of exposure time. For each root, one standard and one with the tube shifted distally in 30°, with and without implant, totaling 80 radiographs. In addition, 80 CBCT scans were obtained with the OP300 Maxio (FOV 5×5 cm, 90 kVp), with and without implants, for each root. The variable parameters were: low-resolution (LR) (5 mA, 0.2 mm voxel) and high-resolution (HR) (10 mA, 0.085 mm voxel). Five evaluators assessed all images using a 5-point confidence scale. Two-way ANOVA with Sidak's post hoc test was used (P<0.05). Intra- and inter-examiner agreement were assessed with weighted kappa coefficients.

RESULTS

DPT and both CBCT protocols(LR and HR) showed comparable AUC, sensitivity, and specificity (P>0.05). DPT and both CBCT protocols presented AUC, sensitivity, and specificity unaffected by the implant(P>0.05).

CONCLUSION

DPT and both CBCT protocols showed comparable diagnostic accuracy of the second canal regardless of zirconia implant presence.

Для цитирования: Andrade-Bortoletto Maria Fernanda Silva, de Oliveira Fernanda Rodrigues, Silva Thaísa Pinheiro, Réa Marcela Tarosso, Leal Renata Maira de Souza, Ruiz Débora Costa, Freitas Deborah Queiroz. Comparison between dual-angle periapical technique and cone-beam computed tomography in the identification of a second canal in mandibular incisors in the presence of a zirconia implant: An in vitro study.. Imaging science in dentistry. 2026. DOI: 10.5624/isd.20260111.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.