MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.08.13.26360358

Медицинская библиотека · medRxiv : the preprint server for health sciences · 2026

Diagnostic accuracy of point-of-care urine tenofovir test, and associations between metrics of tenofovir use and treatment outcomes in a community ART programme.

Naidu Lisanthini, Tlhaku Kwena, Govender Katya, Sookrajh Yukteshwar, Moodley Pravikrishnen, van der Molen Johan, Samsunder Natasha, Lewis Lara, Gandhi Monica, Drain Paul K, Butler Christopher C, Hayward Gail, Garrett Nigel, Dorward Jienchi

СтатьяПрепринтПеревод пока не подготовлен

Аннотация

BACKGROUND

Urine tenofovir (uTFV) and dried blood spot (DBS) tenofovir diphosphate (TFV-DP) concentrations respectively estimate short- and medium-term adherence to tenofovir disoproxil fumarate (TDF)-based antiretroviral therapy (ART). We evaluated the accuracy of a point-of-care uTFV assay, and associations between uTFV/TFV-DP, and viral load (VL) and retention outcomes within a South African community ART programme.

METHODS

We measured uTFV and DBS TFV-DP concentrations using liquid chromatography-tandem mass spectrometry (LC-MS/MS). We calculated sensitivity and specificity of the point-of-care uTFV assay at the manufacturer-recommended threshold of ≥1,500 ng/mL compared to LC-MS/MS. We assessed associations of the point-of-care uTFV assay, and DBS TFV-DP concentrations with concurrent viraemia, and with retention-in-care by 16 weeks post-enrolment.

RESULTS

Of 196 adults median age was 44 years, 127 (64.8%) were female, and 191 (97.4%) were receiving TDF. 185 (94.4%) had detectable point-of-care uTFV, which had high sensitivity (99.5%, 95% CI 96.5-100%) and moderate specificity (76.9%, 95% CI 46.0-93.8%) for detecting uTFV ≥1,500 ng/mL. Two participants had concurrent viraemia ≥1,000 copies/mL; of these 50.0% (95% CI 9.4-90.5) had undetectable point-of-care uTFV, and 100% (95% CI 19.7-100) had low TFV-DP <483 fmol/punch. Among participants without viraemia 97.4% (95% CI 93.6-99.0) had detectable uTFV, and 98.1% (95.3-99.6) had high TFV-DP ≥483 fmol/punch. Point-of-care uTFV and DBS TFV-DP were not associated with retention-in-care.

CONCLUSIONS

The point-of-care uTFV assay demonstrated high sensitivity and moderate specificity to detect uTFV. Over 95% of people without viraemia had detectable point-of-care uTFV or high DBS TFV-DP levels respectively, but these were not associated with 16-week retention-in-care.

Для цитирования: Naidu Lisanthini, Tlhaku Kwena, Govender Katya, Sookrajh Yukteshwar, Moodley Pravikrishnen, van der Molen Johan, Samsunder Natasha, Lewis Lara, Gandhi Monica, Drain Paul K, Butler Christopher C, Hayward Gail, Garrett Nigel, Dorward Jienchi. Diagnostic accuracy of point-of-care urine tenofovir test, and associations between metrics of tenofovir use and treatment outcomes in a community ART programme.. medRxiv : the preprint server for health sciences. 2026. DOI: 10.64898/2026.08.13.26360358.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.