m+Medelevator.RU
← Поиск публикаций
Neurogastroenterology and motility · 2026

Biomechanical Assessment During High-Resolution Impedance Manometry Enhances Characterization of Inconclusive Esophagogastric Junction Outflow Obstruction.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Smires Aidan D, Kou Wenjun, Pandolfino John E, Pitisuttithum Panyavee, Goudie Eric, Alikhan Muhammed M, Patankar Neelesh A, Carlson Dustin A

Аннотация

BACKGROUND: Esophagogastric junction outflow obstruction (EGJOO) identified on high-resolution manometry (HRM) remains a clinically heterogeneous and inconclusive finding. Additional complementary testing with functional lumen imaging probe (FLIP) or timed barium esophagram (TBE) is recommended to confirm clinically relevant obstruction. We aimed to assess the association of novel Four-Dimensional (4D) HRM metrics against FLIP and TBE outcomes among symptomatic patients with inconclusive EGJOO on HRM.

METHODS: Adult patients with inconclusive HRM-EGJOO who completed corresponding FLIP and TBE studies were identified for inclusion in a cross-sectional, retrospective study. Primary 4D HRM metrics of EGJ opening, EGJ distensibility index (4D EGJ-DI), and 4D maximum EGJ diameter were analyzed relative to reference outcomes defined by FLIP and esophagram.

RESULTS: Among 123 patients (mean age 59 years; 60% female), 4D EGJ-DI and 4D maximum EGJ diameter differed significantly across FLIP and TBE outcome categories (all p < 0.01). Lower 4D EGJ-DI and lower 4D maximum EGJ diameter were associated with reduced EGJ opening on FLIP and abnormal retention on esophagram. There were 0 patients with normal EGJ opening on FLIP that had 4D maximum EGJ diameter < 8.0 mm and 0 patients with reduced EGJ opening on FLIP that had a 4D EGJ-DI > 2.2 mm2/mmHg and 4D maximum EGJ diameter > 10.2 mm.

CONCLUSIONS: By integrating biomechanical assessment of EGJ opening with conventional pressure metrics, 4D HRM provides complementary physiologic information for evaluating esophageal motor function. This additional information may improve characterization of patients with inconclusive EGJOO.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049