MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-026-12932-7

Медицинская библиотека · European radiology · 2026

Lifting the radiomics performance ceiling: how preprocessing leakage amplifies model multiplicity.

García-Hidalgo Clemente, Consentino Hernández José Antonio, Cayuela Espí José Vicente

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To jointly quantify and causally link preprocessing leakage, analytical flexibility and the Rashomon effect in radiomics-based clinical prediction models.

MATERIALS AND

METHODS

Retrospective methodological (specification-curve) analysis of 50 de-identified binary-classification datasets in radMLBench (multicentre; 13 anatomical sites; CT, MRI, PET/CT; median 147 patients per dataset, range 51-969); prediction-model reporting followed CLAIM 2.0 and TRIPOD + AI 2024. We enumerated an analytical multiverse of 456 pipeline specifications (3 scalers × 2 correlation filters × 19 feature selectors × 4 classifiers), each evaluated against the dataset label by 5-fold cross-validation × 10 repetitions. Feature-level preprocessing leakage was assessed by paired global-versus-nested comparison for the synthetic minority oversampling technique (SMOTE), normalisation, correlation filtering and principal component analysis (PCA), pooled by DerSimonian-Laird meta-analysis. Within-subjects causal mediation (43 datasets) tested whether inflation of the best area under the receiver operating characteristic curve (AUC) explains leakage-induced Rashomon-set expansion.

RESULTS

Across the 50 datasets, SMOTE leakage inflated AUC by a pooled 0.09 (95% confidence interval (CI): 0.07, 0.11; p < 0.001), exceeding 0.05 in 64%. Pipeline choice shifted AUC by 0.30, classifier dominating (eta-squared = 0.21). At ε = 5%, near-optimal pipelines disagreed on 20-30% of patient classifications (Fleiss kappa = 0.58) and shared < 30% of top features. SMOTE leakage quadrupled the Rashomon set (0.06 to 0.23; p < 0.001); 79% mediated by best-AUC inflation. Radiomics showed 4.8× wider vibration of effects (VoE) but 13× smaller Rashomon ratios than eight tabular benchmarks (both p < 0.001).

CONCLUSION

The three sources compound; leakage amplifies model multiplicity by inflating the performance ceiling.

KEY POINTS: Question Whether preprocessing leakage, analytical flexibility and the Rashomon effect jointly compromise the reproducibility of radiomics-based clinical prediction models has not been quantified. Findings Across 50 radiomics datasets, SMOTE leakage inflated AUC by 0.09 and quadrupled the Rashomon set, with 79% causally mediated by best-AUC inflation. Clinical relevance Radiomics-derived clinical prediction models routinely disagree on 20-30% of patients while appearing equally near-optimal. The released three-layer audit tool quantifies this risk per study and should precede any clinical deployment claim.

Для цитирования: García-Hidalgo Clemente, Consentino Hernández José Antonio, Cayuela Espí José Vicente. Lifting the radiomics performance ceiling: how preprocessing leakage amplifies model multiplicity.. European radiology. 2026. DOI: 10.1007/s00330-026-12932-7.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.