MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12630-026-03172-w

Медицинская библиотека · Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026

Intraoperative ventilation settings in Germany: an observational multicentre cross-sectional study.

Grüßer Linda, Keszei András, Rossaint Rolf, Zingraf Berit, Wallqvist Julia, Goldmann Sebastian, Coburn Mark, Güldner Andreas, Hachenberg Thomas, Hönemann Christian, Koch Thea, Mierke Bert, Schuster Martin, Wrigge Hermann, Schuler Julia, Larmann Jan, Kowark Ana, NO-HARM Study Group, German Society of Anaesthesiology and Intensive Care (GSAIC) Trials Group

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Intraoperative lung protective ventilation and, in inhalational anesthesia, minimal fresh gas flow (FGF) are recommended. It remains unclear how these recommendations are transferred to clinical routine. We aimed to assess corresponding anesthesia practices in Germany and raise awareness of optimal ventilation settings.

METHODS

We performed a pragmatic prospective observational national cross-sectional assessment of intraoperative ventilation settings in Germany, followed by an educational intervention and follow-up assessment. The intervention consisted of a pocket card designed in a Delphi-process. The patient-centred primary endpoint was tidal volume (VT)·kg-1 ideal body weight (IBW), and the environment-centred primary endpoint was FGF in inhalational anesthesia. In a post hoc analysis, we grouped departments into quintiles of baseline VT and FGF, and explored changes after the intervention.

RESULTS

Over 240 of 1,148 anesthesiology departments participated (21%). We collected data from 2,198 operating rooms in the first (preintervention) and 2,106 in the second (postintervention) assessment (96% response rate). The mean (standard deviation) VT·kg-1 IBW was 7.4 (1.4) mL in the first assessment vs 7.3 (1.3) mL in the second assessment. The median [interquartile range (IQR)] FGFs were 0.60 [0.50-0.85] L·min-1 vs 0.50 [0.45-0.75] L·min-1, respectively. Exploratory multilevel regression analysis did not show an effect of the intervention. In the anesthesiology departments whose baseline ventilation settings were in the highest quintile, the intervention was associated with improvements in both VT and FGF.

CONCLUSIONS

This large-scale clinical study of intraoperative ventilation settings in Germany found that most anesthesiologists already followed current recommendations. Therefore, for the entire cohort, no major improvements were observed. The educational intervention might improve ventilation settings in anesthesiology departments whose baseline practice deviates strongly from current recommendations.

Для цитирования: Grüßer Linda, Keszei András, Rossaint Rolf, Zingraf Berit, Wallqvist Julia, Goldmann Sebastian, Coburn Mark, Güldner Andreas, Hachenberg Thomas, Hönemann Christian, Koch Thea, Mierke Bert, Schuster Martin, Wrigge Hermann, Schuler Julia, Larmann Jan, Kowark Ana, NO-HARM Study Group, German Society of Anaesthesiology and Intensive Care (GSAIC) Trials Group. Intraoperative ventilation settings in Germany: an observational multicentre cross-sectional study.. Canadian journal of anaesthesia = Journal canadien d'anesthesie. 2026. DOI: 10.1007/s12630-026-03172-w.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.