Equation-derived SMI not generalizable for DXA-defined low muscle mass in Chinese adults: external validation study.

Liu Zhenchao, Shi Gudi, Ren Yuqian, Wang Yun, Zhao Xinbo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Anthropometric equations are commonly used to estimate appendicular skeletal muscle mass (ASM) when direct body-composition measurements are unavailable. However, it remains unclear whether skeletal muscle index derived from predicted ASM (SMI_pred) can validly identify low muscle mass using thresholds developed for dual-energy X-ray absorptiometry (DXA). We externally validated the Wen et al. anthropometric equation against DXA in Chinese adults undergoing routine health examinations.

METHODS

This single-center retrospective external validation study included 501 Chinese adults who underwent whole-body DXA between 2016 and 2022. The published equation was applied without coefficient updating to calculate predicted ASM (ASM_pred), and SMI_pred was calculated as ASM_pred divided by height squared. Validation included Pearson correlation, Lin's concordance correlation coefficient (CCC), calibration, Bland-Altman agreement, and classification of DXA-defined low muscle mass by direct application of the Asian Working Group for Sarcopenia 2019 sex-specific DXA cut-offs. Simple linear recalibration was evaluated using repeated 10-fold cross-validation as a secondary analysis.

RESULTS

ASM_pred was strongly correlated with DXA-measured ASM (Pearson r = 0.892, 95%CI = 0.873-0.909; CCC = 0.862), but systematically overestimated ASM, with a mean bias of 1.25 kg and 95% limits of agreement from -3.14 to 5.64 kg. Its calibration slope was 0.853 (95%CrI = 0.815-0.891). SMI_pred showed lower correlation and concordance with DXA-measured SMI (Pearson r = 0.756, 95%CI = 0.716-0.791; CCC = 0.705), a mean bias of 0.457 kg/m2, 95% limits of agreement from -1.19 to 2.10 kg/m2, and a calibration slope of 0.738. The difference between the ASM and SMI correlations was 0.136 (bootstrap 95%CI = 0.111-0.164; P = 0.0002). Direct application of AWGS 2019 DXA cut-offs to SMI_pred yielded a sensitivity of 0.211 and specificity of 0.963, missing 97 of 123 DXA-defined low-muscle-mass cases. Cross-validated recalibration reduced prediction error but did not eliminate individual-level disagreement.

CONCLUSION

The Wen equation preserved strong association with DXA-measured absolute ASM but showed systematic bias and limited individual-level agreement. Performance deteriorated after derivation of SMI, and direct transfer of DXA-based AWGS thresholds to SMI_pred resulted in substantial under-detection of low muscle mass. Neither the original nor the locally recalibrated equation should be used as a stand-alone substitute for DXA when classification depends on fixed muscle-mass thresholds. Any use within a multivariable screening pathway requires separate validation of the complete screening rule.

Для цитирования: Liu Zhenchao, Shi Gudi, Ren Yuqian, Wang Yun, Zhao Xinbo. Equation-derived SMI not generalizable for DXA-defined low muscle mass in Chinese adults: external validation study.. Frontiers in nutrition. 2026. DOI: 10.3389/fnut.2026.1887277.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.