MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm14165814

Медицинская библиотека · Journal of clinical medicine · 2025

Evaluating the Efficacy of a Novel Titanium Cage System in ALIF and LLIF: A Retrospective Clinical and Radiographic Analysis.

Turlip RW, Dagli MM, Chung RJ, Chauhan D, Kim RJ, Kincaid J, Ahmad HS, Ghenbot Y, Yoon JW

Перевод в очереди

Аннотация

Background/

Objectives

The success of lumbar interbody fusion depends on the implant design and the surgical approach used. This study evaluated the clinical and radiographic outcomes of lateral lumbar interbody fusion (LLIF) and anterior lumbar interbody fusion (ALIF) using a 3D-printed porous titanium interbody cage system.

Methods

A retrospective, single-center review of 48 patients treated for degenerative lumbar spine disease was conducted. Patients underwent LLIF, ALIF, or a combination of both using a 3D-printed titanium cage system (J&J MedTech, Raynham, MA, USA). The Oswestry disability index (ODI) and Patient-Reported Outcomes Measurement Information System (PROMIS) metrics were assessed after 6 weeks, 3 months, 6 months, and 12 months. Linear mixed-effects models evaluated the pre- and post-operative differences. Fusion performance and complications were assessed using the Bridwell grading system over 24 months.

Results

A total of 78 levels (62 LLIF and 16 ALIF) were analyzed. Fusion rates were 90.3% (56/62) for LLIF levels and 81.3% (13/16) for ALIF levels by the end of 12 months. ODI scores improved significantly after 3 months (MD -13.0, p p p p p p p = 0.032) and 12 months (MD +4.9, p

Conclusions

This novel interbody cage demonstrated high fusion rates, significant pain and function improvements, and a favorable safety profile, warranting further comparative studies.

Для цитирования: Turlip RW, Dagli MM, Chung RJ, Chauhan D, Kim RJ, Kincaid J, Ahmad HS, Ghenbot Y, Yoon JW. Evaluating the Efficacy of a Novel Titanium Cage System in ALIF and LLIF: A Retrospective Clinical and Radiographic Analysis.. Journal of clinical medicine. 2025. DOI: 10.3390/jcm14165814.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.