MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/qims-23-1834

Медицинская библиотека · Quantitative imaging in medicine and surgery · 2024

Application of three-dimensional (3D) magnetic resonance (MR) Multi-Echo iN Steady-state Acquisition sequences in preoperative evaluation of lumbar disc herniation: a prospective study.

Pan X, Wen Y, Huang K, Li J, Li W, Yan W, Wen D, Zhang M, Wang S, Zhang X, Li Z, Rong X

Перевод в очереди

Аннотация

BackgroundConventional spinal magnetic resonance imaging (MRI) cannot provide accurate diagnosis and surgical planning; thin-layer scanning can enhance the diagnostic efficacy. This study aimed to investigate the value of 3-dimensional (3D) magnetic resonance (MR) in preoperative evaluation of lumbar disc herniation, with a focus on the application of Multi-Echo iN Steady-state Acquisition (MENSA) sequence.MethodsA total of 51 patients who underwent lumbar disc herniation surgery in West China Hospital of Sichuan University from June 2021 to December 2021 were prospectively enrolled. A cross-sectional study was conducted on those patients. The Cube group was scanned using 3D-FSE-Cube sequence, the Cube stir group was scanned using 3D-FSE-Cube Short Tau Inversion Recovery (STIR) sequence, and the MENSA group was scanned using MENSA sequence. Signal and noise values of nerve, herniated disc, ligamentum flavum (LF), and soft tissue were measured on the 3 groups. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Objective scores were calculated by analysis of variance (ANOVA). Image quality was scored by a 5-point method. Friedman test was used to compare subjective scores, and Kappa test was used to evaluate the consistency of 2 readers' scores.ResultsThe nerve root SNRs in the MENSA and Cube stir groups were higher than that in the Cube group (PConclusionsThe preoperative 3D MRI MENSA sequence can clearly depict the nerve roots and offer desirable contrast between the nerve roots, LF, bone, and intervertebral discs (IVDs). Patients with lumbar degeneration can effectively benefit from MENSA sequence since it provides useful imaging information to help understand disc herniation and compression of adjacent tissues when developing preoperative surgical strategies.

Для цитирования: Pan X, Wen Y, Huang K, Li J, Li W, Yan W, Wen D, Zhang M, Wang S, Zhang X, Li Z, Rong X. Application of three-dimensional (3D) magnetic resonance (MR) Multi-Echo iN Steady-state Acquisition sequences in preoperative evaluation of lumbar disc herniation: a prospective study.. Quantitative imaging in medicine and surgery. 2024. DOI: 10.21037/qims-23-1834.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.