MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm13072048

Медицинская библиотека · Journal of clinical medicine · 2024

Restoration of Range of Motion in the Cervical Spine through Single-Segment Artificial Disc Replacement Using the Baguera®C Prosthesis.

Tsai MC, Liu YF, Lin WH, Lee MC

Перевод в очереди

Аннотация

Background

Anterior cervical discectomy and fusion (ACDF) is a standard procedure for degenerative diseases of the cervical spine, providing nerve decompression and spinal stabilization. However, it limits cervical spine motility, restricts fused segment activity, and may lead to adjacent degeneration. Cervical disc arthroplasty (CDA) is an accepted alternative that preserves the structure and flexibility of the cervical spine. This study aimed to explore the dynamic changes in the range of motion (ROM) of the cervical spine after CDA using a viscoelastic artificial disc, as well as the factors affecting mobility restoration.

Methods

A retrospective analysis was conducted on 132 patients who underwent single-level anterior cervical discectomy and CDA from January 2015 to June 2022. Result: Analysis of data from 132 patients revealed a significant improvement in clinical outcomes. The mean ROM of C2-C7 and functional spinal unit (FSU) segments significantly increased from 2 to 36 months post-operatively. Cervical spine flexibility was preserved and enhanced after prosthesis implantation. However, it took six months for the cervical spine motility to stabilize. In addition, sex and age were found to impact motility restoration, with female and younger patients exhibiting larger ROMs post-surgery. Additionally, CDA at the C5-C6 level resulted in the greatest increase in ROM, potentially improving overall kinematic ability.

Conclusions

Single-segment artificial disc arthroplasty effectively restores the ROM in degenerative cervical spine conditions.

Для цитирования: Tsai MC, Liu YF, Lin WH, Lee MC. Restoration of Range of Motion in the Cervical Spine through Single-Segment Artificial Disc Replacement Using the Baguera®C Prosthesis.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13072048.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.