Minimally invasive quantification of [18F]MC225 PET using constrained simultaneous estimation of the input function.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Providência Laura, Somsen Joost F, Van Der Weijden Chris W, Mossel Pascalle, Salvi De Souza Giordana, Dierckx Rudi A, Luurtsema Gert, Lammertsma Adriaan A, Tsoumpas Charalampos

Аннотация

OBJECTIVE: [18F]MC225 is a PET radiotracer used to assess P-glycoprotein function at the bloodbrain barrier. [18F]MC225 PET quantification requires arterial catheterization to obtain the plasma input function, an invasive procedure. The simultaneous estimation of the input function (SIME) has been proposed as a technique for estimating the plasma input function, however, it requires at least one venous/arterial blood sample. Long axial field-of-view (LAFOV) PET scanners enable a variation of the SIME algorithm, the constrained SIME (cSIME), that incorporates information from whole-blood activity, potentially eliminating the need for blood sampling. In this study, we evaluated the feasibility of cSIME for quantifying the [18F]MC225 in the brain using a clinical dataset.

APPROACH: Dynamic data from seven subjects scanned on a LAFOV PET system following injection of [18F]MC225 were included. The constrained SIME method was used to estimate the plasma input function of each subject. A whole-blood input function extracted from the ascending aorta was used as the initial estimate, and multiple brain regions were simultaneously fitted to estimate the parameters required to convert the whole-blood input function into a plasma input function. Volume of distribution (VT) values were calculated using both the ground-truth and cSIME-estimated plasma input functions with a reversible two-tissue compartment model.

MAIN RESULTS: Without a blood sample,VTestimates using the cSIME plasma input function resulted in relative differences ranging between approximately -26% and 11% compared to theVTestimates obtained with the measured plasma input function. Incorporating one blood sample as anchor at 60 minutes decrease these relative differences to 11%.

SIGNIFICANCE: The findings of this study suggest that cSIME may help reduce the invasiveness of quantitative [18F]MC225 PET studies. The clinical relevance of the observed bias will ultimately depend on its magnitude relative to disease-related differences in kinetic parameters expected in patient populations.