A Monolithically Integrated Multimodal Low-Artifact Neural Probe for Optogenetic Applications.

Yang Xien, Li Xiaodong, Zhao Wenbo, Cao Xin, Li Yang, Wen Ye, Ding Yanyuan, Huang Xilei, Li Zeyi, Weng Jiefeng, Li Haoran, Pun Sio Hang, Zhang Baijun

СтатьяПеревод пока не подготовлен

Аннотация

In optogenetic neural probes, stimulus light intensity monitoring, thermal safety assessment, and stimulation artifact suppression are of critical importance for achieving cell-type-specific optical modulation and high-fidelity neural signal recording. Here, micro light-emitting diode (µLED) stimulation sources and photodetectors (PDs) were fabricated on a GaN-based blue LED epitaxial structure on a sapphire substrate, and resistance temperature detectors (RTDs) and metal recording electrodes were monolithically integrated to form a multimodal neural probe. A dual electromagnetic shielding cage formed by metal layers and the n+-GaN layer encloses the LED drive and recording interconnects. The RTD‑equipped LED delivers an irradiance of 26.5 mW mm-2 at 0.2 mA, and the PD yields a response voltage of 0.036 V in a brain‑mimicking agar phantom. The RTD exhibits a temperature sensitivity of 2.601 Ω °C-1, and the local temperature rise stays below 1°C. Under irradiance above 50 mW mm-2, the dual cage combined with transient pulse shaping reduces the average artifact from 260 to 8.75 µV, approaching the system noise floor. In vitro simulated recordings in PBS demonstrate stable recording and basic discrimination of simulated neural-like waveforms under LED stimulation. This work lays a foundation for multimodal integration and low-artifact recording in optogenetic neural probes.

Для цитирования: Yang Xien, Li Xiaodong, Zhao Wenbo, Cao Xin, Li Yang, Wen Ye, Ding Yanyuan, Huang Xilei, Li Zeyi, Weng Jiefeng, Li Haoran, Pun Sio Hang, Zhang Baijun. A Monolithically Integrated Multimodal Low-Artifact Neural Probe for Optogenetic Applications.. Small methods. 2026. DOI: 10.1002/smtd.71108.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.