MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00604-026-08444-2

Медицинская библиотека · Mikrochimica acta · 2026

Colorimetric/chemiluminescent vertical flow immunoassay based on multifunctional cobalt-gold bimetallic nanoclusters for Brucella antibody detection and deep learning-assisted semiquantitative analysis.

Bi Hamai, Zhao Xiaogang, Wei Mingjie, Li Xia, Wu Jiahui, Wang Yuankun, Zhang Xindi, Ma Halifei, Zhou Hengxuan, Xu Zhihua, Guo Kedong, Jiang Yali, Shi Feng

СтатьяПеревод пока не подготовлен

Аннотация

A colorimetric/chemiluminescent vertical flow immunoassay (VFI) for Brucellosis was developed using glutathione-protected cobalt-gold nanoclusters conjugated with staphylococcal protein A (GSH@Co-AuNCs-SPA) as multifunctional catalytic immunoprobes. The nanocluster probe integrates antibody recognition with peroxidase-like catalytic activity, enabling three complementary signal readouts within a common immunorecognition architecture: direct colorimetric visualization, TMB-H₂O₂-amplified colorimetry, and luminol-H₂O₂ chemiluminescence.The prepared GSH@Co-AuNCs exhibited H₂O₂-mediated catalytic activity and sustained chemiluminescent emission, with a detectable visual signal persisting for more than 150 min, thereby providing a broad acquisition window for low-background imaging. Serial-dilution experiments showed experimentally determined signal-discrimination thresholds of 0.5 IU mL⁻¹ for direct colorimetry and 0.2 IU mL⁻¹ for both TMB-amplified colorimetry and chemiluminescence. For the chemiluminescent mode, analysis of 20 independent blank measurements yielded a statistical limit of detection of 0.134 IU mL⁻¹. Under the same analytical dilution-series conditions, a commercial colloidal-gold lateral-flow assay produced a visually distinguishable signal down to 20 IU mL⁻¹.To improve the consistency of image interpretation, shared-weight dual-branch ResNet-18 regression models were established for both TMB and chemiluminescent images. Grouped five-fold cross-validation yielded mean R² values of 0.8746 ± 0.0784 and 0.8907 ± 0.0588, with four-level grading accuracies of 96.25 ± 2.10% and 93.00 ± 6.28% for the TMB and chemiluminescent models, respectively. In a preliminary evaluation of 30 clinical serum samples, TMB-amplified colorimetry showed 95.0% sensitivity, 90.0% specificity, and 93.3% overall agreement with the serum agglutination test (SAT), whereas chemiluminescence showed 95.0%, 100%, and 96.7%, respectively.The proposed platform integrates catalytic signal amplification, complementary optical readouts, and regression-based semiquantitative interpretation within a single VFI system. This strategy provides a practical framework for improving weak-signal discrimination and standardized interpretation in rapid anti-Brucella antibody screening, while further validation in larger independent clinical cohorts remains necessary.

Для цитирования: Bi Hamai, Zhao Xiaogang, Wei Mingjie, Li Xia, Wu Jiahui, Wang Yuankun, Zhang Xindi, Ma Halifei, Zhou Hengxuan, Xu Zhihua, Guo Kedong, Jiang Yali, Shi Feng. Colorimetric/chemiluminescent vertical flow immunoassay based on multifunctional cobalt-gold bimetallic nanoclusters for Brucella antibody detection and deep learning-assisted semiquantitative analysis.. Mikrochimica acta. 2026. DOI: 10.1007/s00604-026-08444-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.