MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1063/5.0350758

Медицинская библиотека · The Review of scientific instruments · 2026

Design of a diamond-based in-vessel soft x-ray camera system for the SPARC tokamak.

Normile S, Vezinet D, Frandeen B, Perks C, Bombarda F, Verona-Rinati G, Rice J E

СтатьяПеревод пока не подготовлен

Аннотация

Soft x-ray tomography has been used in tokamaks for decades to interrogate a wide variety of phenomena; however, the standard silicon diodes coupled with beryllium filters will not be able to survive the high heat and neutron fluxes present in burning plasma devices like SPARC. Presented here is the design for a set of soft x-ray tomography cameras that use chemical vapor deposition (CVD) single-crystal diamonds and graphene filters for photodetection. Four of these cameras will be placed in the port plugs of SPARC with a large enough view of the poloidal cross section to enable tomographic inversion and sufficient time resolution to resolve the dynamics of low-m and -n magnetohydrodynamic modes. CVD diamonds have been used successfully for the detection of both vacuum ultraviolet and soft x-ray photons at the Frascati Tokamak Upgrade and have demonstrated the ability to maintain greater than 50% of their initial responsivity at a neutron fluence of 1016 cm-2. The neutron dose in SPARC will exceed this limit, providing a demonstration of how CVD diamonds fail in place while adding value to the early operation of a new tokamak. Numerical simulations indicate that graphene spectral filters will filter nearly as effectively as traditional beryllium ones and are able to resist significantly higher heat fluxes due to graphene's unique thermal properties. Simulated plasma emissivity profiles have been used to optimize both the camera placement and detector properties.

Для цитирования: Normile S, Vezinet D, Frandeen B, Perks C, Bombarda F, Verona-Rinati G, Rice J E. Design of a diamond-based in-vessel soft x-ray camera system for the SPARC tokamak.. The Review of scientific instruments. 2026. DOI: 10.1063/5.0350758.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.