MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2026.130684

Медицинская библиотека · Talanta · 2026

Portable microcontroller-based impedance analyzer equipped with molecularly imprinted polymer for sensitive and specific detection of amyloid beta.

Hongoeb Juthamas, Phopin Kamonrat, Tantimongcolwat Tanawut, Ruankham Waralee, Mukhopadhyay Subhas Chandra

СтатьяПеревод пока не подготовлен

Аннотация

Alzheimer's disease (AD) is a progressive neurodegenerative condition with a rising global prevalence. Although clinical immunoassays offer high sensitivity, their dependence on costly and centralized infrastructure hinders widespread screening in resource-limited regions. Herein, we developed an electrical sensing platform utilizing molecularly imprinted polymers (MIPs) as synthetic receptors to detect a critical biomarker, amyloid beta 40 (Aβ40). The analytical performance was evaluated using impedance measurements through a high-precision benchtop LCR meter and a cost-effective miniaturized impedance evaluation board. This biomimetic sensor enabled sensitive detection of Aβ40 across a tested concentration range of 0.01 - 10 pg/mL with a correlation coefficient (R2) ≥ 0.98 for both impedance devices. Notably, the miniaturized board demonstrated strong parity with the benchtop system, yielding limit of detection (LOD) values of 0.19 pg/mL for the miniaturized board and 0.12 pg/mL for the benchtop LCR meter. Furthermore, spiked analysis in human serum and artificial cerebrospinal fluid (aCSF) showed relative errors below 10% at all tested concentrations. As a proof-of-concept achieved with only a 15-min analysis, this study offers a sensitive, portable, and cost-effective platform that shows promise for decentralized screening applications, thereby holding the potential to significantly improve patient outcomes.

Для цитирования: Hongoeb Juthamas, Phopin Kamonrat, Tantimongcolwat Tanawut, Ruankham Waralee, Mukhopadhyay Subhas Chandra. Portable microcontroller-based impedance analyzer equipped with molecularly imprinted polymer for sensitive and specific detection of amyloid beta.. Talanta. 2026. DOI: 10.1016/j.talanta.2026.130684.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.