MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhazmat.2026.143837

Медицинская библиотека · Journal of hazardous materials · 2026

Wireless portable detection of hazardous triethylamine vapor at near-room temperature via ZnO nanoflowers functionalized with titanium-oxo cluster.

Lv Xintong, Li Feng, Yang Ying, Li Dan, Yu Hui, Dong Xiangting, Wang Tianqi

СтатьяПеревод пока не подготовлен

Аннотация

Triethylamine (TEA) is a widely used industrial solvent, yet its high volatility and toxicity pose significant risks to occupational safety and environmental air quality, with a recommended workplace exposure limit of 10 ppm. Real-time, low-temperature monitoring of TEA remains challenging for metal oxide semiconductor sensors, which require elevated operating temperatures. Herein, we report a ZnO nanoflower sensor functionalized with a classical titanium-oxo cluster [Ti8O8(OMc)16]·2CH3CN (Ti8) that enables sensitive and selective TEA detection at near-room temperature. The ZnO/5% Ti8 sensor achieves a response (Ra/Rg) of 5.29 toward 100 ppm TEA, a 4.3-fold enhancement over pristine ZnO, with a low detection limit of 0.39 ppm. The sensor exhibits a response to TEA at least 3 times higher than that to common interfering vapors and retains 90% of its initial response over 30 days. The enhanced performance is attributed to the Ti8-induced increase in chemisorbed oxygen on the ZnO surface, which provides more active sites for TEA oxidation. As a proof-of-concept demonstration for portable TEA detection, the sensor was integrated into a compact Bluetooth-enabled device capable of wirelessly transmitting response data to a smartphone. This work provides a material design strategy for low-power, portable detection of hazardous TEA for workplace and environmental safety.

Для цитирования: Lv Xintong, Li Feng, Yang Ying, Li Dan, Yu Hui, Dong Xiangting, Wang Tianqi. Wireless portable detection of hazardous triethylamine vapor at near-room temperature via ZnO nanoflowers functionalized with titanium-oxo cluster.. Journal of hazardous materials. 2026. DOI: 10.1016/j.jhazmat.2026.143837.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.