Magnetic Resonance Volumetric Quantification of Vestibular Endolymphatic Hydrops in Patients with Unilateral Definite Meniere's Disease Using 3D Inversion Recovery with Real Reconstruction (3D-REAL-IR) Sequence.

Suárez-Vega Víctor, Manrique-Huarte Raquel, Dominguez Pablo, Blanco Melissa, Alonso-Burgos Alberto, Pérez-Fernández Nicolás

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The 3D-REAL-IR MRI sequence allows for an in vivo visualization of endolymphatic hydrops. Qualitative assessment methods of the severity of vestibular and cochlear hydrops are the most commonly used.

METHODS

A quantitative volumetric measurement of vestibular EH in patients with definite unilateral Ménière's disease using the 3D-REAL-IR sequence and the calculation of the endolymphatic ratio (ELR) was intended.

RESULTS

Volumetric calculations of the vestibules, vestibular endolymph and vestibular ELR are performed in 96 patients with unilateral Ménière's disease and correlated with classic qualitative grading scales.

CONCLUSIONS

Quantitative volumetric measurement of vestibular hydrops using the 3D-REAL-IR sequence is feasible and reproducible in daily clinical practice. Vestibular ELR values exceeding 60% defined radiologically significant vestibular hydrops, while values below 30% defined radiologically non-significant vestibular hydrops.

Для цитирования: Suárez-Vega Víctor, Manrique-Huarte Raquel, Dominguez Pablo, Blanco Melissa, Alonso-Burgos Alberto, Pérez-Fernández Nicolás. Magnetic Resonance Volumetric Quantification of Vestibular Endolymphatic Hydrops in Patients with Unilateral Definite Meniere's Disease Using 3D Inversion Recovery with Real Reconstruction (3D-REAL-IR) Sequence.. Journal of clinical medicine. 2023. DOI: 10.3390/jcm12185965.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.