m+Medelevator.RU
← Поиск публикаций
Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2013

Semi-quantification of endolymphatic size on MR imaging after intravenous injection of single-dose gadodiamide: comparison between two types of processing strategies.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Naganawa Shinji, Suzuki Kojiro, Nakamichi Rei, Bokura Kiminori, Yoshida Tadao, Sone Michihiko, Homann Georg, Nakashima Tsutomu, Ikeda Mitsuru

Аннотация

PURPOSE: Many inner ear disorders, including Ménière's disease, are believed to be based on endolymphatic hydrops. We evaluated a newly proposed method for semi-quantification of endolymphatic size in patients with suspected endolymphatic hydrops that uses 2 kinds of processed magnetic resonance (MR) images.

METHODS: Twenty-four consecutive patients underwent heavily T2-weighted (hT2W) MR cisternography (MRC), hT2W 3-dimensional (3D) fluid-attenuated inversion recovery (FLAIR) with inversion time of 2250 ms (positive perilymph image, PPI), and hT2W-3D-IR with inversion time of 2050 ms (positive endolymph image, PEI) 4 hours after intravenous administration of single-dose gadolinium-based contrast material (IV-SD-GBCM). Two images were generated using 2 new methods to process PPI, PEI, and MRC. Three radiologists contoured the cochlea and vestibule on MRC, copied regions of interest (ROIs) onto the 2 kinds of generated images, and semi-quantitatively measured the size of the endolymph for the cochlea and vestibule by setting a threshold pixel value.

RESULTS: Each observer noted a strong linear correlation between endolymphatic size of both the cochlea and vestibule of the 2 kinds of generated images. The Pearson correlation coefficients (r) were 0.783, 0.734, and 0.800 in the cochlea and 0.924, 0.930, and 0.933 in the vestibule (P<0.001, for all). In both the cochlea and vestibule, repeated-measures analysis of variance showed no statistically significant difference between observers.

CONCLUSION: Use of the 2 kinds of generated images generated from MR images obtained 4 hours after IV-SD-GBCM might enable semi-quantification of endolymphatic size with little observer dependency.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты